Skip to end of metadata
Go to start of metadata
You are viewing an old version of this page. View the current version. Compare with Current ·  View Page History

These instructions should assist in configuring your Panasonic DBS Series to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.

Connection information Description
Connection type Serial Output: Panasonic DBS PBX sends SMDR information via a serial connection. You will need to directly connect a serial cable from the Panasonic DBS PBX to the PC that NetPBX is installed and running on.
Cable configuration Null-modem/Crossover.

Configuring your SMDR

Below you will find instructions on how to configure your Panasonic DBS Series to output SMDR to TIM Plus. You will need to do this from the Operator phone:

  1. Press the ON/OFF key.
  2. Press the RECALL key.
  3. Press # #. You are now in Programming mode.
  4. Navigate to Call logging/Remote programming parameters.
  5. Go to Call logging-parity check and select 1 and then press the # key.
  6. Go to Call logging-even/odd parity and select 1 and then press the # key.
  7. Go to Call logging-baud rate (SMDR) and select 4 and then press the # key.
  8. Go to Call logging-stop bit and select 1 and then press the # key.
  9. Go to Call logging-data length and select 4 and then press the # key.
  10. Got to Call logging-printing selection out/in, select 1 which will give you incoming and outgoing calls.
  11. Go to Call logging-printing selection local/long distance calls, select 1 which will print all outgoing calls and then press the # key.
  12. Press the ON/OFF key and your settings will be saved.

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Panasonic DBS 40:

  1. Browse to TIM Plus as normal and login with your credentials.
  2. Click on the Directory tab.
  3. Click on the site configured during the setup wizard and click Propertiesor create a new site and click Properties.
  4. Panasonic DBS 40
  5. Within the Site Properties window, select Panasonic DBS Series from the PBX model drop-down list.
  6. In the Connection method field select No connection required from the drop-down list.
  7. Finally, click on the Save button.