These instructions should assist in configuring your NEC Aspire to work with TIM Enterprise. If you are not familiar with PBX configuration, please contact your system maintainer.

Connection information Description
Connection type Serial Output or IP: To use a serial connection you will need to have a CTA/CTU adaptor or a NTCPU adaptor installed on your NEC Aspire. You will need to connect a serial cable from the adaptor to the PC that NetPBX is installed and running on.
Cable configuration Straight-through for the CTA/CTU Adaptor and Null-modem/Crossover for the NTCPU serial adaptor.
IP method If the NEC Aspire is configured to send the SMDR information via TCP/IP, the actual installation of TIM Enterprise can be anywhere on the network that the PBX is connected to. The NEC Aspire will need to be configured to output SMDR data via TCP/IP so TIM Enterprise can connect to it. TIM Enterprise will connect to the NEC Aspire on TCP port 23.

Configuring your SMDR

Below you will find details on how to configure the SMDR output on the NEC Aspire. The programming will need to be done via PC Pro/Web Pro:

  1. Login to your PC Pro/Web Pro.
  2. As the NEC Aspire has multiple ways of sending SMDR Data, below are the configuration settings based on each adaptor:
  3. Adaptor Programming code Value Description
    NTCPU - IP 10-12-01 IP address that TIM Enterprise will connect to. NTUCPU Network Setup - IP Address.
    10-20-01 TCP port that TIM Enterprise will connect to. We recommend using 9000 and increment it for each NEC Aspire you configure. LAN Setup for External Equipment.
    NTCPU - Serial 10-21-02 1 NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port, you have three options, 0(4800), 1(9600) and 2(38400).
    35-01-01 1 SMDR Options - Output Port Type.
    CTA/CTU - Serial 15-02-19 1 Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module.
    15-02-20 1 Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(19200).
    35-01-01 4 SMDR Options - Output Port Type.
    35-01-02 Extension number that the CTA/CTU adaptor is attached to. SMDR Options - Output Destination Number.
  4. You also need to configure the following programming codes:
  5. Programming code Value Description
    14-01-06 1 Basic Trunk Data Setup - SMDR Print.
    15-01-03 1 Basic Extension Data Setup - SMDR Print.
    35-01-03 0 SMDR Options - Header Language.
    35-01-04 0 SMDR Options - Omit (Mask) Digits.
    35-01-05 0 SMDR Options - Minimum Number of SMDR Digits.
    35-01-06 0 SMDR Options - Minimum Call Duration.
    35-01-07 0 SMDR Options - Minimum Ringing Time.
    35-01-08 Default SMDR Options - SMDR Format.
    35-02-01 0 SMDR Output Options - Toll Restricted Call.
    35-02-02 1 SMDR Output Options - PBX Calls.
    35-02-03 1 SMDR Output Options - Display Trunk Name or Numbers.
    35-02-04 0 SMDR Output Options - Daily Summary.
    35-02-05 0 SMDR Output Options - Weekly Summary.
    35-02-06 0 SMDR Output Options - Monthly Summary.
    35-02-08 1 SMDR Output Options - Incoming calls.
    35-02-09 0 SMDR Output Options - Print Name or Numbers.
    35-02-10 0 SMDR Output Options - All Lines Busy (ALB) Output.
    35-02-12 0 SMDR Output Options - DID Table Name Output.
    35-02-13 1 SMDR Output Options - CLI Output when DID to Trunk.
    35-02-14 1 SMDR Output Options - Date.
    35-02-15 1 SMDR Output Options - CLI/DID Number Switching.
    35-02-16 1 SMDR Output Options - Print Trunk Name or Received Dialled Number.
    35-02-17 0 SMDR Output Options - Print Account Code or Caller ID Name.
    35-02-18 Default SMDR Output Options - Caller ID Name Output Method.
    80-05-01 1 Date Format for SMDR and System Reports.

Configuring TIM Enterprise

Below you will find steps on how to configure TIM Enterprise to listen for SMDR data from your NEC Aspire:

  1. Browse to TIM Enterprise as normal and login with your credentials.
  2. Click on the Directory tab.
  3. Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'NEC Aspire'.
  4. Left-click on it and select Properties.
  5. From the General settings tab select NEC Aspire from the PBX model list.
  6. NEC Aspire
  7. In the Connection tab select Establish TCP connection to PBX from the Connection method list.
  8. In the Host field enter the IP Address of your NEC Aspire.
  9. Leave Port field blank.
  10. Leave the Username field blank and enter in your Password.
  11. In the IP script field select Generic Simple from the drop-down list.
  12. Finally, click on the Save button.
  13. NEC Aspire