These instructions help you configure your LG iPECS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Plus establishes a TCP connection to this PBX.

Support Files
  LG iPECS.TDT
  LG.TDS
Required Tasks
  Configure the SMDR output
  Configure TIM Plus

Configuring the SMDR output

The SMDR output in LG iPECS is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:

SMDR Attributes (PGM 177)

Save Enable: Leave this is the default which is unticked
Print Enable: This needs to be enabled by clicking on the check box
SMDR Record Call Type: This needs to be set to 'All Calls', you will need to select this from the drop-down list
Records In Detail: This needs to be enabled by clicking on the check box
Print Incoming Call: This needs to be enabled by clicking on the check box
Print Lost Call: This needs to be enabled by clicking on the check box
SMDR Dial Digit Hidden: Leave this as the default which is '0'
SMDR Currency Unit: Leave this as the default which is blank
SMDR Cost Per Metering Pulse: Leave this as the default which is blank
SMDR Fraction: Leave this as the default which is '0'
SMDR Start Time: Leave this as the default which is '0'
SMDR Hidden Digit: Leave this as the default which is 'Right'
Long Distance Call Digit Counter: Leave this as the default which is '0'
Long Distance Code (Max 2 Digits): Leave this as the default
MSN Print on SMDR: Leave this is the default which is unticked
Print Caller Number: This needs to be enabled by clicking on the check box
 

Here is an example of a populated  SMDR Attributes screen:


Printer Port Selection (PGM 175)

In the Printer Port Selection (PGM 175) window, set Info/On-line SMDR to Telnet 1 to send call logging data to TIM Plus over TCP to port 23.

ISDN Attributes (PGM 200)

To enable CLI information in the call records produced by your LG iPECS, you need to set the CLI Print To Serial to ON, as shown below:


Configuring TIM Plus

If your LG iPECS has been configured to send its call logging data via TCP/IP, follow the steps below to configure TIM Plus:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.

  3. In the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field, select Actively connect to PBX from the drop-down list.
  5. In the Host field, enter the IP address of your LG iPECS.
  6. In the Port field, enter 23.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field, select Generic Simple from the drop-down list.
  9. Click on the Save button to apply the settings.