These instructions should assist in configuring your Samsung DCS to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | Serial Output:
The Samsung DCS sends SMDR information via a serial connection, you will need to directly connect a serial cable from the Samsung DCS PBX to the PC that NetPBX is installed and running on.
The Samsung DCS Compact requires a Miscellaneous card for SMDR output. |
Cable configuration | Straight-through. |
Configuring your SMDR
Below you will find instructions on how to configure your Samsung DCS to output SMDR to TIM Plus. You will need to do this from a LCD handset. Just use the down arrow key to move to each option.
- Open Programming and select .
- Program each option as stated below:
- Now press the key.
- Select .
- Dial 0 and use the arrow keys and select SMDR.
- Now press the key.
SMDR field | Value |
---|---|
Page Header | Yes |
Lines per page | 1 |
Incoming Call | Yes |
Outgoing Call | Yes |
Authorise Code | Yes |
SMDR Start Time | Yes |
In/Out Group | No |
DND Calls | No |
Wake-Up Calls | No |
Directory Names | None |
Caller ID Data | Yes |
Abandoned Call | Yes |
No of Dial Mask | 00 |
DID Num/Name | Yes |
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Samsung DCS:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
- Within the Site Properties window, select Samsung DCS from the PBX model drop-down list.
- In the Connection method field select No connection required from the drop-down list.
- Finally, click on the button.