Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The Avaya IP Office version 5 or lower uses the Avaya Delta Server software to configure the SMDR output. If you don't have a copy of the Avaya Delta Server, you should be able to get this from your Avaya Administration CD; otherwise, speak to contact your system maintainer to obtain a copy.

Info

 The Avaya Delta Server is known to be backward compatible with older version versions of the Avaya IP Office as far back as v3.x.

HTML
<a id="Configure Avaya Delta Server"></a>

...

  1. On the computer running Delta Server, open a web browser and navigate to: http://127.0.0.1:8080.
  2. Ensure that Delta Server is connected to your Avaya IP Office by verifying that Comms Status is displaying Comms Restored. Alternatively, select the Comms option from the left-hand side menu and click on the Search button.  When the system finds your Avaya IP Office unit, select it from the Connection drop-down list and click Apply.
  3. When connected, click on the SMDR option from the left-hand menu and configure each of the fields on the SMDR screen, as shown below:
    Screenshotmacro
    Borderfalse
    Shadowfalse
    URL/download/attachments/4817073/avaya_ip_office_1.png
  4. Click on the Apply button for the changes to take effect.

...

  1. Log in to TIM Plus and click on the Directory tab.
  2. Select Choose the site you configured during the setup wizard want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817073/avaya_ip_office_2.png
  3. Within In the Site Properties window, select Avaya IP Office from the PBX model drop-down list.
  4. In the Connection method field, select Actively connect to PBX from the drop-down list.
  5. In the Host field, enter the IP address of the Avaya Delta Server.
  6. In the Port field, enter 8082.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field, select Avaya IP Office from the drop-down list.
  9. Click on the Save button to apply the settings.