These instructions help you configure your BT Pathway to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1 BT Pathway.TDT
Requiredtask1Configure the SMDR output
Requiredtask3Install NetPBX
Requiredtask2Configure TIM Plus
ConnectionSerial connection
RequiredTask1Configure the SMDR output
RequiredTask2Install NetPBX
RequiredTask3Configure TIM Plus

Info

To obtain the BT Pathway.TDT interface file, contact our Technical Support team.

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

To receive SMDR data from your BT Pathway you need to have a BT System Phone and be familiar with how to use it to perform system programming. To enable SMDR output, follow the steps below:

  1. From the programming position, press the phone setup key P and select System programming.
  2. Enter the PIN and select System.
  3. Select Call logging and choose Call logging on.
  4. Press HANDSFREE/MONITOR to finish.
HTML
<a id="Install NetPBX"></a>

Installing NetPBX

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and follow the steps below:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817051/bt_pathway_1.png
  3. In the Site Properties window, select BT Pathway from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.