Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Configuring your SMDR output

The Siemens HiPath 4000 doesn't have By default, the SMDR output enabled by default. Please contact your phone maintainer to enable the data output of a Siemens HiPath 4000 is not enabled.  To enable it for incoming, outgoing and internal calls, contact your system maintainer.

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Below you will find steps on how Follow the steps below to configure TIM Plus to collect the SMDR data from your Siemens HiPath 4000:

  1. Browse to TIM Plus as normal and log in with your credentials.
  2. Click on the Directory tab.
  3. Select Choose the site configured during the setup wizard and clickyou want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.tri-line.com:8090/download/attachments/4817030/siemens_hipath_4000_1.png
  4. Within In the Site Properties window, select Siemens HiCom-HiPath from the PBX model drop-down list.
  5. In the Connection method field, select Actively connect to PBX from the drop-down list.
  6. In the Host field, enter the IP Address address of your Siemens HiPath 4000.
  7. In the Port field, enter in 9000.
  8. Leave the Username and Password fields blank.
  9. In the Connection script field, select Generic Simple from the drop-down list.
  10. Click on the Save button to apply the settings.

...