By default, the SMDR output of your NEC NEAX is not enabled. For more information about enabling and configuring the SMDR output, you should speak to contact your system maintainer.
HTML |
---|
<a id="Configure TIM Plus"></a> |
...
If your NEC NEAX has been configured to send the data via TCP/IPits SMDR data using an IP connection, follow the steps below to configure TIM Plus:
- Click on the tab.
- Choose the site you want to configure and click
Screenshotmacro Border false URL /download/attachments/12583278/nec_neax_1.png . - Within In the Site Properties window, select NEC NEAX from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP address of your NEC NEAX.
- In the Port field, enter 2599.
- Leave the Username and Password fields blank.
- In the Connection script field, select Generic Simple from the drop-down list.
- Click on the button to apply the settings.
...