These instructions help you configure your Panasonic DBS Series phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1Panasonic DBS Series.TDT
ConnectionSerial connection
RequiredTask1Configure the SMDR output
RequiredTask2Install NetPBX
RequiredTask3Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Follow the steps below to configure your Panasonic DBS Series to output SMDR data to TIM Plus. The configuration needs to be performed from the Operator phone:

  1. Press the ON/OFF key.
  2. Press the RECALL key.
  3. Press ## to enter the 
    Referencemacro
    LabelProgramming mode
    .
  4. Navigate to Call logging/Remote programming parameters.
  5. Go to Call logging-parity check and select 1, then press the # key.
  6. Go to Call logging-even/odd parity and select 1, then press the # key.
  7. Go to Call logging-baud rate (SMDR) and select 4, then press the # key.
  8. Go to Call logging-stop bit and select 1, then press the # key.
  9. Go to Call logging-data length and select 4, then press the # key.
  10. Go to Call logging-printing selection out/in and select 1 for the incoming and outgoing calls.
  11. Go to Call logging-printing selection local/long distance calls and select 1 to print all outgoing calls, then press the # key.
  12. Press the ON/OFF key to save the settings.
HTML
<a id="Install NetPBX"></a>

Installing NetPBX

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the steps below:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and clickProperties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817095/panasonic_dbs_1.png
  3. In the Site Properties window, select Panasonic DBS Series from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.