Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Pbxsummary
Supportfiles1Avaya IP Office.TDT
Supportfiles2Avaya IP Office.TDS
Requiredtask1Configure the SMDR output
Requiredtask3Configure Avaya Delta Server
Requiredtask2Configure TIM Plus
ConnectionActive connection
RequiredTask1Configure the SMDR output
RequiredTask2Configure Avaya Delta SeverServer
RequiredTask3Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

...

Info

 The Avaya Delta Server is known to be backward compatible with older version of the Avaya IP Office as far as v3.x.

HTML
<a id="infoConfigure Avaya Delta Server"></a>
Configuring Avaya Delta Server

...

  1. Open your web browser and type in the following in to the address bar: http://127.0.0.1:8080.
  2. Check that the Avaya Delta Server is connected to your Avaya IP Office. To do this, you need to look at the Comms Status, it should say Comms Restored. If it doesn't then you need to click on the Comms link on the left-hand side, then click on the Search button and once it finds your Avaya IP Office unit, select it from the Connection drop-down list and click on the Apply button. This should connect the Avaya Delta Server to the Avaya IP Office you selected.
  3. Now click on the SMDR option on the left-hand side.
  4. You will need to configure each of the fields on the SMDR screen as shown in the image below:
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817073/avaya_ip_office_1.png
  5. Now click on the apply button.
HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to collect the SMDR data from the Avaya Delta Server::

...