Skip to end of metadata
Go to start of metadata

These instructions help you configure your Splicecom Maximiser phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Enterprise establishes a TCP connection to this PBX.

Support Files
  SpliceCom Maximiser.TDT
  SpliceCom Maximiser.TDS
Required Tasks
  Configure the SMDR output
  Configure TIM Enterprise

Configuring the SMDR output

By default, the call logging output of the Splicecom Maximiser is enabled and you do not normally require a password to obtain it.  To protect your call logging data, you can set a Call Logging Password in the System Details screen of your Maximiser's web management interface.  If you decide to set a password, you need to enter this when configuring TIM Enterprise (below).

Your system maintainer may have already set a call logging password for you.

Configuring TIM Enterprise

Follow the steps below to configure TIM Enterprise to collect the SMDR data from your Splicecom Maximiser:

  1. Click on the Directory tab.
  2. Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
  3. A new window will open, displaying the general properties of your PBX object. Select Splicecom Maximiser from the Data format list and tick the Keep a local backup of data box, as shown below:

  4. Click on the Connection tab and select Establish TCP connection to PBX from the Connection method list.
  5. In the Host field, enter the IP address of your Splicecom Maximiser.
  6. In the Port field, enter 4001.
  7. Leave the Username field blank.
  8. If your Maximiser has a call logging password set, enter it in the Password field; if not, leave it blank.
  9. In the IP script field, select Splicecom Maximiser from the drop-down list.
  10. Click on the Save button to apply the settings.

 

Labels: