Skip to end of metadata
Go to start of metadata

These instructions help you configure your NEC Aspire phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Enterprise establishes a serial connection with this PBX.

Support Files
  NEC Aspire.TDT
  NEC Aspire.TDS
Required Tasks
  Configure the SMDR output
  Install NetPBX
  Configure TIM Enterprise

Configuring your SMDR output

Follow the steps below to configure the SMDR output on your NEC Aspire:

  1. Log in to your PC Pro/Web Pro software.
  2. To configure SMDR output by serial port, apply the following settings for each system adapter:

    AdapterProgramming codeValueDescription
    NTCPU - Serial10-21-021NTCPU Hardware Setup - Baud Rate for COM Port. Choose the baud rate from the three available options: 0 = 4800, 1 = 9600, and 2 = 38400
    35-01-011SMDR Options - Output Port Type
    CTA/CTU - Serial15-02-191Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module
    15-02-201Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. Choose from the three available options: 0 = 4800, 1 = 9600, and 2 = 38400
    35-01-014SMDR Options - Output Port Type
    35-01-02Extension number that the CTA/CTU adaptor is attached to.SMDR Options - Output Destination Number
  3. Apply the following settings in the programming sections below:

    Programming codeValueDescription
    14-01-061Basic Trunk Data Setup - SMDR Print.
    15-01-031Basic Extension Data Setup - SMDR Print.
    35-01-030SMDR Options - Header Language.
    35-01-040SMDR Options - Omit (Mask) Digits.
    35-01-050SMDR Options - Minimum Number of SMDR Digits.
    35-01-060SMDR Options - Minimum Call Duration.
    35-01-070SMDR Options - Minimum Ringing Time.
    35-01-08DefaultSMDR Options - SMDR Format.
    35-02-010SMDR Output Options - Toll Restricted Call.
    35-02-021SMDR Output Options - PBX Calls.
    35-02-031SMDR Output Options - Display Trunk Name or Numbers.
    35-02-040SMDR Output Options - Daily Summary.
    35-02-050SMDR Output Options - Weekly Summary.
    35-02-060SMDR Output Options - Monthly Summary.
    35-02-081SMDR Output Options - Incoming calls.
    35-02-090SMDR Output Options - Print Name or Numbers.
    35-02-100SMDR Output Options - All Lines Busy (ALB) Output.
    35-02-120SMDR Output Options - DID Table Name Output.
    35-02-131SMDR Output Options - CLI Output when DID to Trunk.
    35-02-141SMDR Output Options - Date.
    35-02-151SMDR Output Options - CLI/DID Number Switching.
    35-02-161SMDR Output Options - Print Trunk Name or Received Dialled Number.
    35-02-170SMDR Output Options - Print Account Code or Caller ID Name.
    35-02-18DefaultSMDR Output Options - Caller ID Name Output Method.
    80-05-011Date Format for SMDR and System Reports.

Installing NetPBX

Install and configure NetPBX

Configuring TIM Enterprise

Once NetPBX is configured and collecting data, log in to TIM Enterprise and perform the following steps:

  1. Click on the Directory tab.
  2. Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
  3. A new window will open, displaying the general properties of your PBX object. Select NEC Aspire from the Data format list and tick the Keep a local backup of data box, as shown below:

  4. Click on the Connection tab and select No connection required from the Connection method list.
  5. Click on the Save button to apply the settings.

 

Labels: