<p>These instructions should assist in configuring your Aastra Intelligate Series to 
work with TIM Plus. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>Serial Output or IP: </b>
				If you have configured the Aastra Intelligate to send the SMDR information via a serial connection, you will need to directly connect a serial cable from the Aastra Intelligate to the PC that NetPBX 
				is installed and running on.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Cable configuration</b></td>
			<td class="confluenceTd">Null-modem/Crossover.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>IP method</b></td>
			<td class="confluenceTd"><b>TCP/IP connection: </b>
				If the Aastra Intelligate is configured to send the SMDR information via TCP/IP the actual installation of TIM Plus can be anywhere on the network that the PBX is connected to. The Aastra Intelligate will 
				need to be configured to send the SMDR data to the IP address and TCP port that TIM Enetrprise is listening on.
			</td>
		</tr>
	</tbody>
</table>

<p>For your SMDR configuration, please note that Aastra Intelligate Series has multiple output formats. For TIM Plus, the output will need to be configured to the <span class="reference">PC5 format</span>.</p>

<h2>Configuring TIM Plus</h2>

<p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Aastra Intelligate PC5:</p>

<ol>
	<li>Browse to TIM Plus as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span>or create a new site and click <span class="button no_margin">Properties</span>.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/aastra_intelligate_1.png" alt="Aastra Intelligate PC5" />
	<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">Aastra PC5</span> from the <span class="reference">PBX model</span> drop-down list.</li>
	<li>From the <span class="reference">Connection method</span> drop-down list, select <span class="keyword">Listen for connections from PBX</span>.</li>
	<li>Leave the <span class="reference">Host</span> field blank.</li>
	<li>In the <span class="reference">Port</span> field enter in <span class="keyword">9000</span>.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
</ol>