<p>These instructions should assist in configuring your Siemens HiCom-HiPath to 
work with TIM Enterprise. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>File
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>IP method</b></td>
			<td class="confluenceTd"><b>Swyx - File output: </b>
				The Swyx will output the CDR information to a file. TIM Enterprise can be installed on the same machine as the Swyx server, however we recommend that you speak to your system maintainer to see if there 
				would be any problems in doing this.

				<p>If you have to install TIM Enterprise on to another machine on the network, we advise that you setup a network share for the following directory: 
				<span class="keyword">\program files\tri-line\tim enterprise\spool</span>. You then need to map a network drive on the Swyx server machine to this path.</p>
			</td>
		</tr>
	</tbody>
</table>

<p>For your SMDR configuration, you will need to speak to your system maintainer to enable SMDR output.</p>

<h2>Configuring TIM Enterprise</h2>

<p>Below you will find steps on how to configure TIM Enterprise to listen for SMDR data from your Siemens HiCom-HiPath:</p>

<ol>
	<li>Browse to TIM Enterprise as normal and login with your credentials.</li>
	<li>Click on the <span class="button" id="list">Directory</span> tab.</li>
	<li>Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'Siemens HiCom-HiPath'.</li>
	<li>Left-click on it and select <span class="button" id="list">Properties</span>.</li>
	<li>From the <span class="button" id="list">General</span> settings tab select <span class="keyword">Siemens HiCom-HiPath</span> from the PBX model list.</li>
	<img src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/siemens_hicom_hipath_1.png" alt="Siemens HiCom-HiPath" />
	<li>In the <span class="button" id="list">Connection</span> tab select <span class="keyword">Listen for connection from PBX</span> from the <span class="reference">Connection method</span> list.</li>
	<li>In the <span class="reference">Port</span> field enter in <span class="keyword">9000</span>.</li>
	<li>Finally, click on the <span class="button" id="list">Save</span> button.</li>
	<img src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/siemens_hicom_hipath_2.png" alt="Siemens HiCom-HiPath" />
</ol>