These instructions help you configure your Unify OpenScape Busines phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a>

Configuring the SMDR output

Follow the instructions below to configure the SMDR output in your phone system. These instructions are taken from the Unify OpenScape Business manual.

  1. Log on to OpenScape Business Assistant and click on -> -> , as shown below:
  2. Click to start the wizard.
  3. In the new window that opens, tick the to enable the CDR output, as shown below:
<a id="Set up a DSN connection"></a>

Setting up a DSN connection

The default SMDR output option in the Unify OpenScape Business phone system is . To enable TIM Plus to work with Unify OpenScape Business, you first need to set up a DSN connection, by following the steps below:

  1. Open Windows Control Panel
  2. Double-click on the Administrative tools icon
  3. Double-click on the Data Sources (ODBC) icon to open the ODBC Data Source Administrator window

    For a 64 bit system, access the ODBC Data Source Administrator from the following location C:\Windows\SysWOW64\odbcad32.exe

  4. Click on the System DSN tab
  5. Click on the Add button
  6. Select Native from the driver list and click Finish
  7. In the Data source name field enter Unify OpenScape Business
  8. Click on the OK button to save the changes

An example of an ODBC entry is shown below:

 <a id="Configure the interface file"></a>

Configuring the interface file

Follow the steps below to configure the interface file to establish an HTTPS connection with your Unify OpenScape Business:

  1. Open the Unify OpenScape Business.TDT file, located by default in C:\Program Files\Tri-Line\TIM Plus\config.
  2. Edit the file to point to the IP address of your Unify OpenScape Business and enter the relevant username and password, as shown below:
  3. Remove the apostrophe (') in front of the amended fields to enable them. An example of a configured interface file is shown below:
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once the DSN connection has been set up, log in to TIM Plus and follow the steps below:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
  3. In the Site Properties window, select Unify OpenScape Business from the PBX model drop-down list.
  4. In the Connection method field, select Connect to a system DSN from the drop-down list.
  5. In the DSN name field, select Unify OpenScape Business from the drop-down list.
  6. In the Frequency field, enter 5.
  7. In the DB script field, select Unify OpenScape Business from the drop-down list.
  8. Click on the Save button to apply the settings.