These instructions help you configure your Siemens OpenOffice phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a>

Configuring your SMDR output

By default, the SMDR output of a Siemens OpenOffice phone system is not enabled. For information about how to configure the output for incoming, outgoing and internal calls, contact your system maintainer.

<a id="Configure the interface file"></a>

Configure the interface file

Follow the steps below to configure the interface file to establish an HTTPS connection with your Siemens OpenOffice:

  1. Open the file, located by default in .
  2. Edit the file to point to the IP address of the phone system and enter the relevant username and password of your Siemens OpenOffice, as shown below.
  3. Remove the apostrophe (') in front of the edited fields, to enable the amended fields. An example of a configured interface file is shown below:

 

<a id="Set up a DSN connection"></a>

Setting up a DSN connection

To enable TIM Enterprise to work with the Siemens OpenOffice, you first need to set up a DSN connection, by following the steps below:

  1. Open Windows Control Panel.
  2. Double-click on the Administrative tools icon.
  3. Double-click on the Data Sources (ODBC) icon.
  4. Click on the System DSN tab.
  5. Click on the Add button.
  6. Select Native from the driver list and click Finish.
  7. In the Data source name field enter Siemens OpenOffice.
  8. Click on the OK button to save the changes.

An example of an ODBC entry is shown below:

<a id="Configure TIM Enterprise"></a>

Configuring TIM Enterprise

Once the DSN connection has been set up, log in to TIM Enterprise and perform the following steps:

  1. Click on the Directory tab.
  2. Choose the PBX object you want to configure and click Properties.
  3. A new window will open. In the General tab, select Siemens OpenOffice from the Data format list and tick the Keep a local backup of data box, as shown below:
  4. In the Connection tab, select System DSN connection from the Connection method list.
  5. In the DSN field, select Siemens OpenOffice from the drop-down list.
  6. In the Frequency field, enter to check for data every five seconds.
  7. In the DB script field, select Siemens from the drop-down list.
  8. Click on the Save button to apply the settings.