These instructions help you configure your LG iPECS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a>

Configuring the SMDR output

The SMDR output in LG iPECS is disabled by default. To enable the output, you need to amend the settings under the following programming codes:

SMDR Attributes (PGM 177)

Save Enable: Leave this is the default which is unticked
Print Enable: This needs to be enabled by clicking on the check box
SMDR Record Call Type: This needs to be set to 'All Calls', you will need to select this from the drop-down list
Records In Detail: This needs to be enabled by clicking on the check box
Print Incoming Call: This needs to be enabled by clicking on the check box
Print Lost Call: This needs to be enabled by clicking on the check box
SMDR Dial Digit Hidden: Leave this as the default which is '0'
SMDR Currency Unit: Leave this as the default which is blank
SMDR Cost Per Metering Pulse: Leave this as the default which is blank
SMDR Fraction: Leave this as the default which is '0'
SMDR Start Time: Leave this as the default which is '0'
SMDR Hidden Digit: Leave this as the default which is 'Right'
Long Distance Call Digit Counter: Leave this as the default which is '0'
Long Distance Code (Max 2 Digits): Leave this as the default
MSN Print on SMDR: Leave this is the default which is unticked
Print Caller Number: This needs to be enabled by clicking on the check box
 

Here is an example of a populated  SMDR Attributes screen:

Printer Port Selection (PGM 175)

In the  window, set Info/On-line SMDR to Telnet 1 to allow connections on TCP port 23.

ISDN Attributes (PGM 200)

To enable CLI information in the call records produced by your LG iPECS, you need to set the  to , as shown below:

<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Follow the steps below to configure TIM Plus to listen for SMDR data from your LG iPECS:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
  3. In the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field, select Listen for connections from PBX from the drop-down list.
  5. Ensure that the Host field is blank.
  6. In the Port field, enter 23.
  7. Click on the Save button to apply the settings.