These instructions help you configure your LG IPLDK phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a>

Configuring your SMDR output

The SMDR output on the LG IPLDK is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:

Print Serial Port Selection (PGM 175)

In this window, set Info/On-line SMDR to Telnet 1 to send call logging data to TIM Plus over TCP to port 23.

SMDR Attributes (PGM 177)

Set the SMDR Attributes as shown below:

ISDN Attributes (PGM 200)

Set the ISDN Attributes as shown below, ensuring that the CLI Print to serial field is enabled:

<a id="Configure TIM Plus"></a>

Configuring TIM Plus

If your LG IPLDK has been configured to send its call logging data via TCP/IP, follow the steps below to configure TIM Plus:

  1. Click on the Directory tab.
  2. Choose the site your want to configure and click Properties.
  3. In the Site Properties window, select LG IPLDK from the PBX model drop-down list.
  4. In the Connection method field, select Actively connect to PBX from the drop-down list.
  5. In the Host field, enter the IP address of your LG IPLDK.
  6. In the Port field, enter 23.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field, select Generic Simple from the drop-down list.
  9. Click on the Save button to apply the settings.