Skip to end of metadata
Go to start of metadata
You are viewing an old version of this page. View the current version. Compare with Current ·  View Page History

These instructions help you configure your Mitel SX50 phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Plus establishes a serial connection with this PBX.

Support Files
  Mitel SX50.TDT
  Mitel SX50.TDS
Required Tasks
  $paramRequiredTask1

Configuring your SMDR

By default the Mitel SX50 doesn't have SMDR enabled. To enable SMDR for the Mitel SX50 you need to follow the steps below:

  1. Access the programming interface.
  2. Within the programming interface you need to access Systems Options Programming.
  3. Access Command 100, register 14.
  4. You will be presented with four options. You need to enable Enabled for both incoming and outgoing trunk calls.
  5. Make sure that SMDR is enabled in all of your Class of Services (Command 121-129) and trunk groups (Command 151-156).

Installing NetPBX

The Mitel SX50 phone system sends SMDR information via a serial connection. To collect the data from the serial port and send it to TIM Plus, you will first need to install NetPBX software. For setup instructions, click on the link below:

Install and configure NetPBX

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Select the site configured during the setup wizard and clickProperties.

  3. Within the Site Properties window, select Mitel SX50 from the PBX model drop-down list.
  4. In the Connection method field select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

 


These instructions should assist in configuring your Mitel SX50 to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.

Connection information Description
Connection type Serial Output: Mitel SX50 PBX sends SMDR information via a serial connection. You will need to directly connect a serial cable from the SX50 PBX to the PC that NetPBX is installed and running on.
Cable configuration Straight-through.

Configuring your SMDR

By default the Mitel SX50 doesn't have SMDR enabled. To enable SMDR for the Mitel SX50 you need to follow the steps below:

  1. Access the programming interface.
  2. Within the programming interface you need to access Systems Options Programming.
  3. Access Command 100, register 14.
  4. You will be presented with four options. You need to enable Enabled for both incoming and outgoing trunk calls.
  5. Make sure that SMDR is enabled in all of your Class of Services (Command 121-129) and trunk groups (Command 151-156).

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Mitel SX50:

  1. Browse to TIM Plus as normal and login with your credentials.
  2. Click on the Directory tab.
  3. Click on the site configured during the setup wizard and click Propertiesor create a new site and click Properties.
  4. Mitel SX50
  5. Within the Site Properties window, select Mitel SX50 from the PBX model drop-down list.
  6. In the Connection method field select No connection required from the drop-down list.
  7. Finally, click on the Save button.
Labels: