These instructions help you configure your LG iPECS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1LG iPECS.TDT
Supportfiles2LG.TDS
Requiredtask1Configure the SMDR output
Requiredtask3Install NetPBX
Requiredtask2Configure TIM Plus
ConnectionSerial connection
or
Pbxsummary
Supportfiles1LG iPECS.TDT
Supportfiles2LG.TDS
Requiredtask1Configure the SMDR output
Requiredtask2Configure TIM Plus
ConnectionListening connection

Configuring your SMDR

The LG iPECS by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.

SMDR Attributes (PGM 177)

Within this window you need to set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG iPECS on TCP port 23 to receive SMDR data.

Below is an example of the SMDR Attributes window:

Screenshotmacro
Borderfalse
Shadowfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817110/lg_ipecs_1.png

Printer Port Selection (PGM 175)

Below is an example of the Programming Port Selection window:

Screenshotmacro
Borderfalse
Shadowfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817110/lg_ipecs_2.png

Serial output

HTML
<a id="info"></a>
Installing NetPBX

If your LG iPECS has been configured to send SMDR data via a serial connection, you will first need to install NetPBX software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPBX

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817110/lg_ipecs_4.png
  3. Within the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field select No connection required from the drop-down list
  5. Click on the Save button to apply the settings.

IP output

Configuring TIM Plus

If your LG iPECS has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817110/lg_ipecs_3.png
  3. Within the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field select Listen for connections from PBX from the drop-down list.
  5. In the Host field enter in the IP Address of your LG iPECS.
  6. In the Port field enter in 23.
  7. Click on the Save button to apply the settings.

...

The LG iPECS can be configured to send its SMDR data over a serial (RS232) or an IP connection. Click on one of the links below that relates to your preferred connection method.