Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Pbxsummary
Supportfiles1Panasonic KX Family-TD Series.TDT
Supportfiles2Panasonic KX Family-TD Series.TDS
ConnectionSerial connection
RequiredTask1Configure the SMDR output
RequiredTask2Install NetPBX
RequiredTask3Configure TIM Plus

...

Follow the instructions below to configure your Panasonic KX-TD Series phone system to output SMDR data to TIM Plus. The configuration needs to be performed from one of the a Digital Proprietary Telephone (DPT) : such as the KX-T7431, KX-T7433, KX-T7436, KX-T7230, KX-T7235.

  1. Press PROG. + * + # and enter your System Password.Enter the 
    Buttonmacro
    LabelPROG
     + 
    Buttonmacro
    Label*
     + 
    Buttonmacro
    Label#
      buttons simultaneously, then enter your system password.
  2. Enter programming mode 800 and press the Next button.
  3. Press the Select button to change set the Outgoing: Off option  option to All, then click on the Store button. Click Next.
  4. Press the Select button to change the Incoming: Off option set the Incoming option to All, then press the Store button.
  5. Press the End button to complete the configuration.

...

The Panasonic KX-TD Series phone system sends SMDR information via a serial connection. To collect the call logging data from the serial port and send it to TIM Plus, you first need to install the NetPBX netpbx software. For setup instructions, click on the link below:

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

...

Once NetPBX is configured and collecting call logging data, log in to TIM Plus and perform the steps below:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/48170964817097/panasonic_kx_ta_1.png
  3. In the Site Properties window, select Panasonic KX Family-TD Series from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.