These instructions help you configure your Alcatel OmniPCX Office phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1Alcatel OminPCX Office.TDT
Supportfiles2Alcatel OminPCX Office.TDS
Requiredtask1Configure the SMDR ouput
Requiredtask3Install NetPbx
Requiredtask2Configure TIM Plus
ConnectionSerial connection
or

Configuring your SMDR

Below you will find instructions on how to configure the SMDR output via serial or TCP/IP. These instructions are taken from the Alcatel OmniPCX Office manual:

Alcatel-Lucent OmniPCX Office Communication Server supports two types of call metering:

  • V24 metering supports V24 printing for all call metering tickets.
  • IP metering supports IP printing for call metering tickets originating from a 3rd party application (Business or Hotel) via an IP connection.

The type of metering must be specified when the Office Link driver is installed. The driver can be installed in one of two modes: hotel or metering. You can use the OMC Counting function to specify the type of call metering for hardcopy printouts.

To set printing options for call metering tickets, please follow the steps below:

  1. Open the Counting function window in the OMC console and select the 
    Buttonmacro
    LabelAccounting Printout
    tab.
  2. Select the metering type from the drop-down box: 
    Keywordmacro
    LabelExt. Accounting Activation IP
    or
    Keywordmacro
    LabelExt. Accounting Activation V24
    , and ensure that the associated checkbox is checked.
  3. When finished, click 
    Buttonmacro
    LabelOK
    .

The table below presents a summary of data output from Alcatel:

Screenshotmacro
Borderfalse
URLhttp://178.32.50.115:8090/download/attachments/4817041/alcatel_pbxs.png

HTML
<a id="info"></a>

 

Serial output

Installing NetPBX

If your Alcatel OmniPCX Office has been configured to send SMDR data via a serial connection, you will first need to install NetPbx software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPbx

Configuring TIM Plus

Once NetPbx is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the 
    Buttonmacro
    LabelDirectory
    tab.
  2. Select the site configured during the setup and click 
    Buttonmacro
    LabelProperties
  3. Within the Site properties window, select
    Keywordmacro
    LabelAlcatel OmniPCX Office
    from the PBX model drop-down list.
    Screenshotmacro
    Borderfalse
    URLhttp://178.32.50.115:8090/download/attachments/4817043/alcatel_omnipcx_enterprise_3.png
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the
    Buttonmacro
    LabelSave
    button to apply the changes.
HTML
<a id="info1"></a>

IP output

Alcatel Office Link Driver

If your Alcatel OmniPCX Office has been configured to send SMDR data via IP, you will first need to install the Alcatel Office Link Driver to output the data.

For information on how to install the Alcatel Office Link Driver, please refer to the Alcatel OmniPCX Office manual.

Setting up a DSN connection for TIM Plus

To get TIM Plus to work with the Alcatel Office Link Driver, you will need to setup a DSN connection . Below you will find instructions on how to do this within Microsoft Windows:

  1. Click on Windows 
    Buttonmacro
    LabelStart
    .
  2. Click on 
    Buttonmacro
    LabelControl Panel
    .
  3. Double click on 
    Buttonmacro
    LabelAdministrative Tools
    icon.
  4. Double click on
    Buttonmacro
    LabelData Sources (ODBC)
    icon.
  5. Click on the
    Buttonmacro
    LabelSystem DSN
    tab.
  6. Click on the
    Buttonmacro
    LabelAdd
    button.
  7. Select
    Referencemacro
    LabelNative
    from the list and click 
    Buttonmacro
    LabelFinish
    .
  8. In the 
    Referencemacro
    LabelName
    field enter:
    Keywordmacro
    LabelTIM Plus - Alcatel OHL
    .
  9. In the
    Referencemacro
    LabelDatabase name
    field enter: 
    Keywordmacro
    LabelNative
     .
  10. Click on the
    Buttonmacro
    LabelOK
    button and then again to close the window.

Now you will be able to see the 

Keywordmacro
LabelTIM Plus - Alcatel OHL
in the
Buttonmacro
LabelSystem DSN
list.

An example of ODBC setup is shown below:

Screenshotmacro
Borderfalse
URLhttp://178.32.50.115:8090/download/attachments/4817043/alcatel_omnipcx_office_1.png

 

Configuring TIM Plus

Once the DSN connection has been setup, log on to TIM Plus as usual and apply the following settings:

...

Buttonmacro
LabelDirectory

...

Buttonmacro
LabelProperties

...

Screenshotmacro
Borderfalse
URLhttp://178.32.50.115:8090/download/attachments/4817043/alcatel_omnipcx_office_2.png

...

Buttonmacro
LabelSave

...

The Alcatel OmniPCX Office can be configured to send its SMDR data over a serial (RS232) connection or it can be outputted to a file. Click on one of the links below that relates to your preferred connection method.

No CSTA license is required but you will need to turn on metering over Serial or IP. For IP connections you will need the Alcatel office link driver software. Set all subscribers to all calls (just outbound by default).