hese instructions help you configure your Alcatel PmniPCX Enterprise phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1Alcatel OmniPCX Enterprise.TDT
Supportfiles2Alcatel OmniPCX Enterprise.TDS
Requiredtask1Configure the SMDR output
Requiredtask3Install NetPbx
Requiredtask2Configure TIM Plus
ConnectionSerial connection

or

Pbxsummary
Supportfiles1Alcatel OmniPCX Enterprise.TDT
Supportfiles2Alcatel OmniPCX Enterprise.TDS
Requiredtask1Configure the SMDR output
Requiredtask2Configure TIM Plus
ConnectionActive connection

Configuring your SMDR

Below you will find instructions on how to configure the SMDR output via serial or TCP/IP. These instructions are taken from the Alcatel OmniPCX Enterprise manual:

Connect to your PBX via telnet and follow the steps below:

  1. Applications (
    Buttonmacro
    LabelEnter
    ).
  2. Accounting (
    Buttonmacro
    LabelEnter
    ).
  3. Review/ Modify (
    Buttonmacro
    LabelEnter
    ).
  4. All instance (
    Buttonmacro
    LabelF1
    ).
  5. Realtime ticket output: Set this to

    Keywordmacro
    Labelethernet
    . Note that if you don't have appropriate license, you can only select V24 (serial) here.

  6. Save changes and exit.

The table below presents a summary of data output from Alcatel:

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817041/alcatel_pbxs.png

Configuring TIM Plus

Serial output

If your Alcatel PmniPCX Enterprise has been configured to send SMDR data via a serial connection, you will first need to install NetPbx software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPbx

Once NetPbx is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the
    Buttonmacro
    LabelDirectory
    tab.
  2. Click on the site configured during the setup and click
    Buttonmacro
    LabelProperties
    .
  3. Within the
    Referencemacro
    LabelSite Properties
    window, select the
    Keywordmacro
    LabelAlcatel OmniPCX Enterprise
    from the
    Referencemacro
    LabelPBX model
    drop-down list.
  4. In the 
    Referencemacro
    LabelConnection method
    field, select the
    Keywordmacro
    LabelNo connection required
    from the drop-down list.
  5. Click on the
    Buttonmacro
    LabelSave
    button to apply the settings.
TCP/IP output

If your Alcatel OmniPCX Enterprise has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:

...

Buttonmacro
LabelDirectory

...

Buttonmacro
LabelProperties

...

Referencemacro
LabelSite Properties

...

Keywordmacro
LabelAlcatel PmniPCX Enterprise

...

Referencemacro
LabelPBX model

...

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817042/alcatel_omnipcx_enterprise_1.png

...

Referencemacro
LabelConnection method

...

Keywordmacro
LabelActively connet to PBX

...

  1. In the Connection method field select Actively connect to PBX from the drop-down list.
  2. In the Host field enter the IP Address of your Alcatel OmniPCX Enterprise.
  3. In the Port field enter in 2533.
  4. Leave the Username and Password fields blank.
  5. In the Connection script field select Alcatel OmniPCX Enterprise 7.1+ from the drop-down list.
  6. Finally, click on the Save button.

 

 

 

...

The Alcatel OmniPCX Enterprise can be configured to send its SMDR data over a serial (RS232) or an IP connection. Click on one of the links below that relates to your preferred connection method. Set all subscribers to all calls (just outbound by default).