Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

These instructions help you configure your Siemens OpenOffice phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
RequiredTask4Configure TIM Plus
Supportfiles1Siemens OpenOffice.TDT
Supportfiles2Siemens OpenOffice.TDS
Supportfiles3Siemens OpenOffice.DBS
ConnectionDSN connection
RequiredTask1Configure the SMDR output
RequiredTask2Set up a DSN connection
RequiredTask3Configure TIM Plusthe interface file

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

The Siemens OpenOffice doesn't have By default, the SMDR output enabled by default. Please contact your phone of a Siemens OpenOffice is not enabled. Contact your system maintainer to enable the data output it for incoming, outgoing and internal calls.

HTML
<a id="Set up a DSN connection"></a>

Setting up a DSN connection

To enable TIM Plus to work with the Siemens OpenOffice, you first need to set up a DSN connection. Below you will find instructions on how to do this within Microsoft Windows:

...

, by following the steps below:

  1. Open Windows Control Panel
  2. Double-click on the Administrative tools icon
  3. Double-click on the Data Sources (ODBC) icon to open the ODBC Data Source Administrator window

    Info

    For a 64 bit system, access the ODBC Data Source Administrator from the following location C:\Windows\SysWOW64\odbcad32.exe

  4. Click on the System DSN tab.
  5. Click on the Add button.
  6. Select Native from the driver list and click Finish.
  7. In the Data source name field enter the following: enter Siemens OpenOffice.
  8. Click on the OK button and then again to close save the window.

Now you will be able to see the Siemens OpenOffice in the System DSN list.

  1. changes

An example of an ODBC setup entry is shown below: 

...

Screenshotmacro
 
Border

...

false
URL/download/attachments/4817029/siemens_openoffice_1.png

HTML
<a id="Configure the interface file"></a>

Configuring the interface file

Follow the steps below to configure the interface file to establish an HTTPS connection with your Siemens OpenOffice:

  1. Open the
    Referencemacro
    LabelSiemens OpenOffice.TDT
    file, located by default in
    Referencemacro
    LabelC:\Program Files (x86)\Tri-Line\TIM Plus\config
    .
  2. Edit the file to point to the IP address of your Siemens OpenOffice and enter the relevant username and password, as shown below:
    Screenshotmacro
    URL/download/attachments/4817029/siemens_openoffice_4.png
  3. Remove the apostrophe (') in front of the amended fields to enable them. An example of a configured interface file is shown below:
    Screenshotmacro
    URL/download/attachments/4817029/siemens_openoffice_5.png
HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once the DSN connection has been set up, log in to TIM Plus and follow the steps below:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817029/siemens_openoffice_2.png
  3. In the Site Properties window, select Siemens OpenOffice from the PBX model drop-down list.
  4. In the Connection method field, select Connect to a system DSN from the drop-down list.
  5. In the DSN name field, select Siemens OpenOffice from the drop-down list.
  6. In the Frequency field, enter 5.
  7. In the DB script field, select Siemens from the drop-down list.
  8. Click on the Save button to apply the settings.