Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

These instructions help you configure your Aastra Intelligate phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Connection2Serial connection
Supportfiles1Aastra PC5.TDT
Supportfiles2Aastra PC5.TDS
Requiredtask1Configure the SMDR output
Requiredtask3Install NetPbx
Requiredtask2Configure TIM Plus
ConnectionListening connection
Additionaltasks1Install NetPBX - if connecting via a serial cable

Configuring your SMDR

For your SMDR configuration, please note that Aastra Intelligate Series has multiple output formats. For TIM Plus, the output will need to be configured to 

Keywordmacro
LabelPC5
format.

Below are some screenshots examples of how the Aastra Intelligate should be configured.

Setting the SMDR format to PC5

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817024/aastra_intelligate_1.png

Setting the SMDR format to TCP/IP

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817024/aastra_intelligate_2.png

OIP Server and TIM Plus

The OIP server has a very basic

Referencemacro
Labelcall logging
module. If you are intending on installing TIM Plus along side the OAI server you need to uninstall the 
Referencemacro
Labelcall logging
module from the OIP server suit. If you do not uninstall this, you will find that if you configure your Aastra to output to the TIM Plus PC, the OIP server will overwrite it with its required settings.

HTML
<a id="info"></a>

Configuring TIM Plus

Serial output

If your Aastra Intelligate has been configured to send SMDR data via a serial connection, you will first need to install NetPbx software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPbx

Once NetPbx is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the
    Buttonmacro
    LabelDirectory
    tab.
  2. Select the site configured during the setup and click
    Buttonmacro
    LabelProperties
    .
  3. Within the
    Referencemacro
    LabelSite properties
    window, select
    Keywordmacro
    LabelAastra PC5
    from the
    Referencemacro
    LabelPBX model
    drop-down list.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817024/aastra_intelligate_4.png
  4. In the
    Referencemacro
    LabelConnection method
    field, select
    Keywordmacro
    LabelNo connection required
    from the drop-down list.
  5. Finally, click on the
    Buttonmacro
    LabelSave
    button to apply the changes.

 

TCP/IP output

If your Aastra Intelligate has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus to listen for SMDR data:

  1. Click on the
    Buttonmacro
    LabelDirectory
    tab.
  2. Select the site configured during the setup wizard and click
    Buttonmacro
    LabelProperties
    .
  3. Within the
    Referencemacro
    LabelSite properties
    window, select
    Keywordmacro
    LabelAastra PC5
    from the
    Referencemacro
    LabelPBX model
    drop-down list.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817024/aastra_intelligate_3.png
  4. In the
    Referencemacro
    LabelConnection method
    field, select
    Keywordmacro
    LabelListen for connection from PBX
    from the drop-down list.
  5. Leave the
    Referencemacro
    LabelHost
    field blank.
  6. In the
    Referencemacro
    LabelPort
    field, enter
    Keywordmacro
    Label9000
    .
  7. Click on the
    Buttonmacro
    LabelSave
    button to apply the changes.

 

...

/2025/2045/2065 can be configured to send its SMDR data over a serial (RS232) or an IP connection. Click on one of the links below that relates to your preferred connection method.