...
Configuring your SMDR output
Using the CAT ( Customer Administration Terminal (CAT), enter the following settings in the system-programming mode, enter the following settings:
Field name | Details | ||
---|---|---|---|
CM40 | Output Default output port & and attributes defaults: 9600 baud, 8 data bits, no parity, 2 stop bits, DTR/RTS flow control. | ||
CM13+05 | Enable SMDR for incoming calls to required stations. | ||
CM13+06 | Enable SMDR for outgoing calls to required stations. | ||
CM35+14 | Enable SMDR for outgoing calls to required trunk routes. | ||
CM35+49 | Enable SMDR for incoming calls to required trunk routes. | ||
CM08 | If SMDR for incoming calls is enabled, specify whether it the setting applies to all incoming calls or only to those with Account Codes. Include that use account codes. Also, include ANI/Caller ID for incoming calls.
|
HTML |
---|
<a id="Install NetPBX"></a> |
Installing NetPBX
If your NEC NEAX has been configured to send SMDR data via To capture SMDR data from your NEC NEAX using a serial connection, you will first need to install the NetPBX software the netpbx software to collect the data from the serial port and send it to TIM Plus. For setup instructions, click on the link below:
HTML |
---|
<a id="Configure TIM Plus"></a> |
...
Once NetPBX is configured and collecting data, log on in to TIM Plus as usual and apply perform the following settingssteps below:
- Click on the tab.
- Select Choose the site configured during the setup wizard you want to configure and click .
Screenshotmacro Border false URL http://docs.tri-line.com:8090/download/attachments/12583276/nec_neax_2.png - Within In the Site Properties window, select NEC NEAX from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Click on the button to apply the settings.