Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The SMDR output in LG iPECS is disabled by default. To  To enable the output, you need to amend the following programming number codessettings in the programming sections below:

SMDR Attributes (PGM 177)
FieldDescription
Save Enable

...

Leave this

...

as the default which is unticked
Print Enable

...

This needs to be enabled by clicking on the check box
SMDR Record Call Type

...

This needs to be set to 'All Calls', you will need to select this from the drop-down list
Records In Detail

...

This needs to be enabled by clicking on the check box
Print Incoming Call

...

This needs to be enabled by clicking on the check box
Print Lost Call

...

This needs to be enabled by clicking on the check box
SMDR Dial Digit Hidden

...

Leave this as the default which is '0'
SMDR Currency Unit

...

Leave this as the default which is blank
SMDR Cost Per Metering Pulse

...

Leave this as the default which is blank
SMDR Fraction

...

Leave this as the default which is '0'
SMDR Start Time

...

Leave this as the default which is '0'
SMDR Hidden Digit

...

Leave this as the default which is 'Right'
Long Distance Call Digit Counter

...

Leave this as the default which is '0'
Long Distance Code (Max 2 Digits)

...

Leave this as the default
MSN Print on SMDR

...

Leave this is the default which is unticked
Print Caller Number

...

This needs to be enabled by clicking on the check box

Here is an example of the a populated SMDR Attributes window screen:

Screenshotmacro
Borderfalse
URL/download/attachments/4817110/lg_ipecs_1.png

...

In the 

Referencemacro
LabelPrinter Port Selection (PGM 175)
window, set Info/On-line SMDR to Telnet 1 to allow connections on TCP port 23.Here is an example of the Programming Port Selection window COM1/COM2 to send call logging data by serial port.

ISDN Attributes (PGM 200)

To enable CLI information in the call records produced by your LG iPECS, you need to set the

Referencemacro
LabelCLI Print To Serial
 to
Keywordmacro
LabelON
, as shown below:

Screenshotmacro
Borderfalse
URL/download/attachments/4817110/lg_ipecs_2.png

...

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

...

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817110/lg_ipecs_43.png
  3. In the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

...