Configure the SMDR output
The SMDR output in LG iPECS is disabled by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.. To enable the output, you need to amend the following settings in the programming sections below:
SMDR Attributes (PGM 177)
Within this window you need to set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG iPECS on TCP port 23 to receive SMDR data.
...
Field | Description |
---|
Save Enable | Leave this as the default which is unticked |
Print Enable | This needs to be enabled by clicking on the check box |
SMDR Record Call Type | This needs to be set to 'All Calls', you will need to select this from the drop-down list |
Records In Detail | This needs to be enabled by clicking on the check box |
Print Incoming Call | This needs to be enabled by clicking on the check box |
Print Lost Call | This needs to be enabled by clicking on the check box |
SMDR Dial Digit Hidden | Leave this as the default which is '0' |
SMDR Currency Unit | Leave this as the default which is blank |
SMDR Cost Per Metering Pulse | Leave this as the default which is blank |
SMDR Fraction | Leave this as the default which is '0' |
SMDR Start Time | Leave this as the default which is '0' |
SMDR Hidden Digit | Leave this as the default which is 'Right' |
Long Distance Call Digit Counter | Leave this as the default which is '0' |
Long Distance Code (Max 2 Digits) | Leave this as the default |
MSN Print on SMDR | Leave this is the default which is unticked |
Print Caller Number | This needs to be enabled by clicking on the check box
|
Here is an example of a populated SMDR Attributes screen:
Screenshotmacro |
---|
Border | false |
---|
URL | http://docs.call-logger.com:8090download/attachments/4817110/lg_ipecs_1.png |
---|
|
Printer Port Selection (PGM 175)
In the
Referencemacro |
---|
Label | Printer Port Selection (PGM 175) |
---|
|
window, set Info/On-line SMDR to COM1/COM2 to send call logging data by serial port.ISDN Attributes (PGM 200)
To enable CLI information in the call records produced by your LG iPECS, you need to set the
to , as shown below: Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817110/lg_ipecs_1.png2.png |
---|
|
HTML |
---|
<a id="Install NetPBX"></a> |
Installing NetPBX
If your LG iPECS has been configured to send SMDR data via a serial connection, you first need to install the netpbx software to collect data from the serial port and send it to TIM Plus. For setup instructions, click on the link below:
Install and configure NetPBX
HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps:
- Click on the Directory tab.
- Choose the site you want to configure and click Properties.
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/4817110/lg_ipecs_3.png |
---|
|
- In the Site Properties window, select LG iPECS from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Click on the Save button to apply the settings.