These instructions help you configure your Aastra Intelligate/2025/2045/2065 phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1Aastra PC5.TDT
Supportfiles2Aastra PC5.TDS
ConnectionSerial connection
RequiredTask1Configure the SMDR output
RequiredTask2Install NetPBX
RequiredTask3Configure TIM Plus

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Info

The Aastra Intelligate/2025/2045/2065 can output SMDR information in multiple formats. You should always select the

Keywordmacro
LabelPC5
format for use with TIM Plus.

Below are some screenshots to demonstrate how the Aastra Intelligate Series should be configured:

 

Setting the SMDR format to PC5

Screenshotmacro
Borderfalse
URL/download/attachments/4817024/aastra_intelligate_1.png

Setting the SMDR format to TCP/IP

Screenshotmacro
Borderfalse
URL/download/attachments/4817024/aastra_intelligate_2.png

Setting the SMDR format to PC5

The OIP Server has a very basic call logging module. If you intend to install TIM Plus alongside the OIP Server, you need to uninstall the call logging module from the OIP Server suite, otherwise, when configuring your Aastra to output the data to the PC running TIM Plus, the OIP Server will overwrite some required settings.

HTML
<a id="Install NetPBX"></a>

Installing NetPBX

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817024/aastra_intelligate_4.png
  3. In the Site Properties window, select Aastra PC5 from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the changes.