Follow the instructions below to configure your BT Versatility for use with TIM PlusEnterprise:

Screenshotmacro

Screenshotmacro

Screenshotmacro

Screenshotmacro

Borderfalse
Shadowfalse
URL/download/attachments/4817052/bt_versatility_1.png

Screenshotmacro
Borderfalse
Shadowfalse
URL/download/attachments/4817052/bt_versatility_2.png

Screenshotmacro
Borderfalse
Shadowfalse
URL/download/attachments/4817052/bt_versatility_3.png

HTML
<a id="InstallingInstall NetPBX"></a>

Installing NetPBX

...

  1. Click on the Directory tab.
  2. Choose Locate the PBX object you want to configure and click in the Director, right-click on it and select Properties.
  3. A new window will open. In the General tab, select AGFEO AC-AS Series , displaying the general properties of your PBX object. Select BT Versatility from the Data format list and tick the the 
    Keywordmacro
    LabelKeep a local backup of data
    box, as shown below:
    Screenshotmacro
  4. In
  5. Borderfalse
    URL/download/attachments/3407902/bt_versatility_1.png
  6. Click on the Connection tab , and select No connection required from the Connection method list.
  7. Click on the Save button to apply the settings.
    Screenshotmacro

...

  1. Border

...

  1. false

 

 

HTML
<p>These instructions should assist in configuring your BT Versatility to 
work with TIM Enterprise. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>Serial Output: </b>
			The BT Versatility sends Call Logging information via a serial connection. The BT Versatility has a V24 port on the CCU. The connection itself is RJ11 and you will need to purchase a V24 module from your 
			system supplier/maintainer. You need to directly connect a serial cable from the V24 module to the PC that NetPBX/TIM Enterprise is installed and running on.
		</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Cable configuration</b></td>
			<td class="confluenceTd">Straight-through.</td>
		</tr>
	</tbody>
</table>

<p>These instructions should assist in configuring your BT Versatility to work with TIM Enterprise. If you are not familiar with PBX configuration, please contact your system maintainer.</p>

<p>The interface to the printer or PC should be serial V24/RS232-C and should meet the following specifications: Speed &ndash; 4800, 9600, 19200, 38400 or 115,200 bps. Data - 8 bits (no parity).</p>

<p>The BT Versatility has an in-built buffer to store the last 500 call records. This buffer can be output to the serial port as required. This option is selected in the system programming.</p>

<p>An X-on X-off signal can be enabled which allows the switch to detect if a device on the serial port, which supports X-on X-off is receiving the data.</p>

<p>Another option allows the last four digits of the dialled number to be masked. This is 'Restricted call logging'.</p>

<h2>Configuring your BT Versatility</h2>

<div style="width: 700px;">
	<img class="screenshot naked" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/bt_versatility_1.png" alt="BT Versatility" />

	<img class="screenshot naked" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/bt_versatility_2.png" alt="BT Versatility" />

	<img class="screenshot naked" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/bt_versatility_3.png" alt="BT Versatility" />
</div>

<h2>Configuring TIM Enterprise</h2>

<p>Below you will find steps on how to configure TIM Enterprise to listen for SMDR data from your BT Versatility:</p>

<ol>
	<li>Browse to TIM Enterprise as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'BT Versatility'.</li>
	<li>Left-click on it and select <span class="button no_margin">Properties</span>.</li>
	<li>From the <span class="button no_margin">General</span> settings tab select <span class="keyword">BT Versatility</span> from the PBX model list.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/bt_versatility_4.png" alt="BT Versatility" />
	<li>In the <span class="button no_margin">Connection</span> tab select <span class="keyword">No connection required</span> from the <span class="reference">Connection method</span> list.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>