These instructions help you configure the SMDR data on your Mitel 5000-7000 phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

...

HTML
<a id="Configure the SMDR output"></a>

Configuring the SMDR output

By default, the Mitel 5000-7000 has its SMDR output disabled. Follow the steps below to enable it:

  1. Log in to the Mitel DB Studio software.
  2. Click and expand the System node.
  3. Click and expand the Cabinet node.
  4. Select the Sockets node.
  5. In the right-hand window, click on the SMDR parameter to set its enabled state to Yes.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/481706316711934/mitel_5000_7000_1.png
  6. Click and expand the System icon.
  7. Click and expand the Maintenance icon.
  8. Click on the SMDR icon.
  9. On the right-hand side you will have the SMDR fields that need to be configured, as shown below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/481706316711934/mitel_5000_7000_2.png

     
HTML
<a id="Configure TIM Enterprise"></a>

Configuring TIM Enterprise

Follow the steps below to configure TIM Enterprise to collect the SMDR data from your Mitel 5000-7000:

  1. Click on the Directory tab.
  2. Choose Locate the PBX object you want to configure and click in the Directory, right-click on it and select Properties.
  3. A new window will open. In the General tab, select , displaying the general properties of your PBX object. Select Mitel 5000-7000 from the Data format list and tick the the 
    Keywordmacro
    LabelKeep a local backup of data
    box, as shown below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/3538969/mitel_5000_7000_1.png
  4. In Click on the Connection tab , and select Establish TCP connection to PBX from the Connection method list.
  5. In the Host field, enter the IP address of your Mitel 5000-7000.
  6. In the Port field, enter 4000.
  7. Leave the Username and Password fields blank.
  8. In the IP script field, select Mitel 5000-7000 from the drop-down list.
  9. Click on the Save button to apply the settings.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/3538969/mitel_5000_7000_2.png

...