Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
HTML
<p>These instructions should assist in configuring your Toshiba CIX/CTX to 
work with TIM Enterprise. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>Serial Output or IP: </b>
				If you have configured your Toshiba CIX/CTX to send SMDR information via a serial connection, you will need to directly connect a serial cable from the Toshiba CIX/CTX PBX to the PC that NetPBX is installed 
				and running on.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Cable configuration</b></td>
			<td class="confluenceTd">Null-modem/Crossover or Straight-through. Please check your Toshiba manual.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>IP method</b></td>
			<td class="confluenceTd"><b>TCP/IP connection: </b>
				If the Toshiba CIX/CTX is configured to send the SMDR information via TCP/IP the actual installation of TIM Enterprise can be anywhere on the network that the PBX is connected to. The Toshiba CIX/CTX will need 
				to be configured to send the SMDR data to the IP address and TCP port that TIM Enterprise is listening on.
			</td>
		</tr>
	</tbody>
</table>

<p>For your SMDR configuration, you will need to speak to your system maintainer to enable SMDR output.</p>

<h2>Configuring TIM Enterprise</h2>

<p>Below you will find steps on how to configure TIM Enterprise to listen for SMDR data from your Toshiba CIX/CTX:</p>

<ol>
	<li>Browse to TIM Enterprise as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'Toshiba CIX/CTX'.</li>
	<li>Left-click on it and select <span class="button no_margin">Properties</span>.</li>
	<li>From the <span class="button no_margin">General</span> settings tab select <span class="keyword">Toshiba CIX/CTX</span> from the PBX model list.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/toshiba_cix_ctx_1.png" alt="Toshiba CIX/CTX" />
	<li>In the <span class="button no_margin">Connection</span> tab select <span class="keyword">Listen for connection from PBX</span> from the <span class="reference">Connection method</span> list.</li>
	<li>In the <span class="reference">Port</span> field enter in <span class="keyword">9000</span>.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/toshiba_cix_ctx_2.png" alt="Toshiba CIX/CTX" />
</ol>

The Toshiba CIX/CTX can be configured to send its SMDR data over a serial (RS232) or an IP connection. Click on one of the links below that relates to your preferred connection method.