- Click on the tab.
- Choose Locate the PBX object you want to configure and click in the Directory, right-click on it and select Properties.
- A new window will open. In the tab, select , displaying the general properties of your PBX object. Select Siemens HiPath DX from the Data format list and tick the Keep a local backup of data box, as shown below:
Screenshotmacro Border false URL /download/attachments/13271550/siemens_hipath_dx_1.png - In Click on the tab , and select Establish TCP connection to PBX from the Connection method list.
- In the Host field, enter the IP address of the System/UPI card of your phone system.
- In the Port field, enter 17257.
- Leave the Username and Password fields blank.
- In the IP script field, select Siemens Realitis DX from the drop-down list.
- Click on the
Screenshotmacro Border false URL /download/attachments/13271552/siemens_hipath_dx_ip.png button to apply the settings.