Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

These instructions help you configure your Avaya BCM phone system (up to v3.x) to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
RequiredTask4Configure TIM Plus
Supportfiles1Avaya BCM.TDT
Supportfiles2Avaya BCM.TDS
Requiredtask1Configure the SMDR output
Requiredtask3Create a CDR User
Requiredtask2Configure TIM Plus
ConnectionActive connection
RequiredTask1Configure the SMDR output
RequiredTask2Create a CDR user
RequiredTask3Install and configure NetPBX

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Follow the steps below to configure your Avaya BCM (up to v3.x) to output SMDR to TIM Plus:

  1. Open your Business Communications Manager Unified Manager.
  2. Click on the Services tree node.
  3. Click on the Call Detail Recording node.
  4. On the right-hand panel the Summary window will appear. Ensure that 
    Keywordmacro
    LabelUp
     is selected in the
    Referencemacro
    LabelStatus
     drop-down list.
  5. Select the Report Parameters tree node and configure the fields as shown below:

    SMDR fieldValue
    FormatNorstar
    Report TypeAll
    LanguageEnglish
    Report FilterAll
  6. Select the Report Options tree node and configure the fields as shown below:

    SMDR fieldValue
    Date FormatMM/DD/YY
    Header FormatLine/Station
    DNIS InfoEnabled
    Connection CharLeave as default
    Clip File ScheduleLeave as default
    Clip File SizeLeave as default
    CDR Disk Space LimitLeave as default
  7. For the Market Parameters settings, please leave as the system defaults.
  8. For the Prefix Bin Options setting please leave as the system defaults.
  9. Once you have completed the above changes, choose
    Buttonmacro
    LabelCommit
     from the Configuration file menu.
HTML
<a id="Create a CDR user"></a>

Creating a CDR User

To enable TIM Plus to connect to your Avaya BCM you will need to create a CDR User in the System option of your BCM Unified Manager configuration utility. The Avaya BCM connection requires the DCOM service to be enabled on the machine running TIM Plus. Following the introduction of enhanced security in Windows XP Service Pack 2, the username and password for the

Referencemacro
LabelCDR User
  now need to be exactly the same as the credentials of the Windows account under which TIM Plus runs.  

HTML
<a id="Install and configure NetPBX"></a>

Installing and configuring NetPBX

To collect the call logging data from the Avaya BCM up to v3.x phone system and send it to TIM Enterprise, you first need to install the NetPBX software.

After the installation, follow the instructions below to set up a connection between BCM and NetPBX:

  1. Make sure the CDRServer.EXE and Interop.CDRSERVERLib.dll files are placed in the same folder as NetPBX.EXE, usually located in {pf}\Tri-Line\NetPBX.
    Screenshotmacro
    URL/download/attachments/10321941/bcm_1.png
  2. Register CDRServer.EXE by running the command line with administrator privileges and typing the following command under the directory path of the NetPBX folder: CDRServer.EXE/regserver.
  3. Open the computer's local security policies: Start -> Control Panel -> Administrative Tools -> Local Security Policy.
    Screenshotmacro
    URL/download/attachments/10321941/bcm_2.png
  4. Within the 
    Referencemacro
    LabelSecurity Settings\Local Policies\Security Options
    tree, change the following items as highlighted in the screenshot below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/10321941/bcm_3.png

    1. Network Access: Let Everyone permissions apply to anonymous users. Set this to Enabled.
    2. Network Access: Sharing security model for local accounts. Set this to Classic.
    3. DCOM: Machine Access Restrictions: Click on Edit Security and add the following user accounts:
      Referencemacro
      LabelAnonymous, Everyone, Interactive, Network, System
      . Set each one to have full access rights.
      Screenshotmacro
      Borderfalse
      Shadowfalse
      URL/download/attachments/10321941/bcm_4.png
  5. Next step is to modify the way DCOM behaves on the computer by executing the DCOM configuration program: Start -> Run -> DCOMCNFG [enter]. Browse the tree to the following location: 
    Referencemacro
    LabelConsole Root -> Component Services -> Computers -> My Computer
    . Righ-click on My Computer for Properties and amend or update the following options:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/10321941/bcm_5.png

    1. On the Default Properties tab:
      Enable Distributed COM on this computer: tick the box for his option
      Default Authentication Level: set this to Connect
      Default Impersonation Level: set this to Identify
      Screenshotmacro
      Borderfalse
      URL/download/attachments/10321941/bcm_6.png
    2. On the COM Security tab:
      Go to the Access Permissions section and select Edit default.
      Add the following accounts and set both local and remote access permissions: 
      Referencemacro
      LabelAnonymous, Everyone, Interactive, Network, Local Service
      and
      Referencemacro
      LabelSystem
      .
      Screenshotmacro
      Borderfalse
      Shadowfalse
      URL/download/attachments/10321941/bcm_7.png

      Go to the Launch and Activation Permissions section and click on Edit default tab.
      Add or update the following accounts to give them all local and remote access permissions: 
      Referencemacro
      LabelAnonymous, Everyone, Interactive, Network, Local Service
        and
      Referencemacro
      LabelSystem
      .
      Screenshotmacro
      Borderfalse
      Shadowfalse
      URL/download/attachments/10321941/bcm_8.png


HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps:

  1. Log in to TIM Plus and click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/4817068/avaya_bcm_1.png
  3. In the Site Properties window, select Avaya BCM from the PBX model drop-down list.
  4. In the Connection method field, select  No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.