These instructions help you configure your Siemens HiCom/HiPath phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Pbxsummary |
---|
Supportfiles1 | Siemens HiCom-HiPath.TDT |
---|
Supportfiles2 | Siemens.TDS |
---|
Connection | Listening connection |
---|
RequiredTask1 | Configure the SMDR output |
---|
RequiredTask2 | Configure TIM Enterprise |
---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
By default, the SMDR output of a Siemens HiCom/HiPath phone system is not enabled. Contact your system maintainer for information about how to configure the SMDR output for incoming, outgoing and internal calls.
HTML |
---|
<a id="Configure TIM Enterprise"></a> |
Follow the steps below to configure TIM Enterprise to listen for SMDR data from your Siemens HiCom/HiPath:
- Click on the Directory tab.
- Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
- A new window will open, displaying the general properties of your PBX object. Select Siemens HiCom-HiPath from the Data format list and tick the
Keywordmacro |
---|
Label | Keep a local backup of data |
---|
|
box, as shown below:
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/13271503/siemens_hicom_hipath_1.png |
---|
|
- Click on the Connection tab and select Listen for connections from PBX from the Connection method list.
- Leave the Host field blank.
- In the Port field, enter 9000.
- Click on the Save button to apply the settings.
Screenshotmacro |
---|
Border | false |
---|
URL | /download/attachments/13271505/siemens_hicom_hipath_ip.png |
---|
|