These instructions help you configure your Siemens HiCom/HiPath phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Pbxsummary
Supportfiles1Siemens HiCom-HiPath.TDT
Supportfiles2Siemens.TDS
ConnectionListening connection
RequiredTask1Configure the SMDR output
RequiredTask2Configure TIM Enterprise

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

By default, the SMDR output of a Siemens HiCom/HiPath phone system is not enabled. Contact your system maintainer for information about how to configure the SMDR output for incoming, outgoing and internal calls.

HTML
<a id="Configure TIM Enterprise"></a>

Configuring TIM Enterprise

Follow the steps below to configure TIM Enterprise to listen for SMDR data from your Siemens HiCom/HiPath:

  1. Click on the Directory tab.
  2. Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
  3. A new window will open, displaying the general properties of your PBX object. Select Siemens HiCom-HiPath from the Data format list and tick the 
    Keywordmacro
    LabelKeep a local backup of data
    box, as shown below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/13271503/siemens_hicom_hipath_1.png
  4. Click on the Connection tab and select Listen for connections from PBX from the Connection method list.
  5. Leave the Host field blank.
  6. In the Port field, enter 9000.
  7. Click on the Save button to apply the settings.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/13271505/siemens_hicom_hipath_ip.png