Configuring your SMDR output

Below you will find details on how Follow the steps below to configure the SMDR output on the NEC XN120. The programming will need to be done via PC Pro/Web Proyour NEC Aspire:

  1. Log in to your PC Pro/Web Pro software.
  2. As the NEC XN120 has multiple ways of sending SMDR Data, below are the configuration settings The NEC XN120 can output its SMDR data in multiple ways. For use with TIM Plus, apply the following configuration settings, based on each adaptor:

    AdaptorProgramming codeValueDescription
    NTCPU - IP10-12-01IP address that TIM Plus will connect to.NTUCPU Network Setup - IP addressAddress.
    10-20-01TCP port that TIM Plus will connect to. We recommend using 9000 and increment it for each NEC XN120 you configure.LAN Setup for External Equipment.
    NTCPU - Serial10-21-021NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(38400).
    35-01-011SMDR Options - Output Port Type.
  3. You also need to configure the following programming codesApply the following settings in the programming sections below:

    Programming codeValueDescription
    14-01-061Basic Trunk Data Setup - SMDR Print.
    15-01-031Basic Extension Data Setup - SMDR Print.
    35-01-030SMDR Options - Header Language.
    35-01-040SMDR Options - Omit (Mask) Digits.
    35-01-050SMDR Options - Minimum Number of SMDR Digits.
    35-01-060SMDR Options - Minimum Call Duration.
    35-01-070SMDR Options - Minimum Ringing Time.
    35-01-08DefaultSMDR Options - SMDR Format.
    35-02-010SMDR Output Options - Toll Restricted Call.
    35-02-021SMDR Output Options - PBX Calls.
    35-02-031SMDR Output Options - Display Trunk Name or Numbers.
    35-02-040SMDR Output Options - Daily Summary.
    35-02-050SMDR Output Options - Weekly Summary.
    35-02-060SMDR Output Options - Monthly Summary.
    35-02-081SMDR Output Options - Incoming calls.
    35-02-090SMDR Output Options - Print Name or Numbers.
    35-02-100SMDR Output Options - All Lines Busy (ALB) Output.
    35-02-120SMDR Output Options - DID Table Name Output.
    35-02-131SMDR Output Options - CLI Output when DID to Trunk.
    35-02-141SMDR Output Options - Date.
    35-02-151SMDR Output Options - CLI/DID Number Switching.
    35-02-161SMDR Output Options - Print Trunk Name or Received Dialled Number.
    35-02-170SMDR Output Options - Print Account Code or Caller ID Name.
    35-02-18DefaultSMDR Output Options - Caller ID Name Output Method.
    80-05-011Date Format for SMDR and System Reports.

 

 

HTML
<a id="Configure TIM Plus"></a>

...

If your NEC Aspire has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:

  1. Log on to TIM Plus as usual and click on Click on the Directory tab.
  2. Select Choose the site configured during the setup wizard you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.tri-line.com:8090/download/attachments/12583311/nec_xn120_1.png
  3. Within the Site Properties window, select NEC DXE from the PBX model drop-down list.
  4. In the Connection method field, select Actively connect to PBX from the drop-down list.
  5. In the Host field, enter the IP address of your NEC XN120.
  6. In the Port field, enter in the port configured in the programming code 10-20-01.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field, select Generic Simple from the drop-down list.
  9. Click on the Save button to apply the settings.

...