Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
HTML
<p>These instructions should assist in configuring your NEC XN120 to 
work with TIM EnterprisePlus. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>Serial Output or IP: </b>
				If you have configured the NEC XN120 to send the SMDR information via a serial connection, you will need to directly connect a serial cable from the NEC XN120 to the PC that NetPBX is installed and running on.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Cable configuration</b></td>
			<td class="confluenceTd">Null-mode/Crossover or Straight-through. Please check your NEC XN120 manual.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>IP method</b></td>
			<td class="confluenceTd">If the NEC XN120 is configured to send the SMDR information via TCP/IP, the actual installation of TIM EnterprisePlus can be anywhere on the network that the PBX is connected to. 
			The NEC XN120 will need to be configured to output SMDR data via TCP/IP so TIM EnterprisePlus can connect to it. TIM EnterprisePlus will connect to the NEC XN120 on a specific TCP port.
			</td>
		</tr>
	</tbody>
</table>

<h2>Configuring your SMDR</h2>

<p>Below you will find details on how to configure the SMDR output on the 
NEC XN120. The programming will need to be done via PC Pro/Web Pro:</p>

<ol>
	<li>Login to your PC Pro/Web Pro.</li>
	<li>As the NEC XN120 has multiple ways of sending SMDR Data, below are the configuration settings based on each adaptor:</li>
	<table class="confluenceTable">
		<tbody>
			<tr>
				<th class="confluenceTh">Adaptor</th>
				<th class="confluenceTh" width=130>Programming code</th>
				<th class="confluenceTh" width=274>Value</th>
				<th class="confluenceTh">Description</th>
			</tr>
			<tr>
				<td class="confluenceTd" rowspan="2"><b class="blue">NTCPU - IP</b></td>
				<td class="confluenceTd"><b>10-12-01</b></td>
				<td class="confluenceTd">IP address that TIM EnterprisePlus will connect to.</td>
				<td class="confluenceTd">NTUCPU Network Setup - IP Address.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>10-20-01</b></td>
				<td class="confluenceTd">TCP port that TIM EnterprisePlus will connect to. We recommend using <span class="keyword">9000</span> and increment it for each NEC XN120 you configure.</td>
				<td class="confluenceTd">LAN Setup for External Equipment.</td>
			</tr>
			<tr>
				<td class="confluenceTd" rowspan="2"><b class="blue">NTCPU - Serial</b></td>
				<td class="confluenceTd"><b>10-21-02</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(38400).</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-01-01</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">SMDR Options - Output Port Type.</td>
			</tr>
		</tbody>
	</table>
	<li>You also need to configure the following programming codes:</li>
	<table class="confluenceTable">
		<tbody>
			<tr>
				<th class="confluenceTh" width=130>Programming code</th>
				<th class="confluenceTh" width=48>Value</th>
				<th class="confluenceTh">Description</th>
			</tr>
			<tr>
				<td class="confluenceTd"><b>14-01-06</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">Basic Trunk Data Setup - SMDR Print.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>15-01-03</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">Basic Extension Data Setup - SMDR Print.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-01-03</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Options - Header Language.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b> 35-01-04</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Options - Omit (Mask) Digits.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-01-05</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Options - Minimum Number of SMDR Digits.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-01-06</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Options - Minimum Call Duration.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-01-07</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Options - Minimum Ringing Time.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-01-08</b></td>
				<td class="confluenceTd">Default</td>
				<td class="confluenceTd">SMDR Options - SMDR Format.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b> 35-02-01</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Output Options - Toll Restricted Call.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b> 35-02-02</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">SMDR Output Options - PBX Calls.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-03</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">SMDR Output Options - Display Trunk Name or Numbers.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-04</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd"> SMDR Output Options - Daily Summary.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-05</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Output Options - Weekly Summary.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-06</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Output Options - Monthly Summary.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-08</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">SMDR Output Options - Incoming calls.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-09</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Output Options - Print Name or Numbers.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-10</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Output Options - All Lines Busy (ALB) Output.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-12</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Output Options - DID Table Name Output.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-13</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">SMDR Output Options - CLI Output when DID to Trunk.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-14</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">SMDR Output Options - Date.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-15</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">SMDR Output Options - CLI/DID Number Switching.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-16</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">SMDR Output Options - Print Trunk Name or Received Dialled Number.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-17</b></td>
				<td class="confluenceTd"><span class="keyword">0</span></td>
				<td class="confluenceTd">SMDR Output Options - Print Account Code or Caller ID Name.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>35-02-18</b></td>
				<td class="confluenceTd">Default</td>
				<td class="confluenceTd">SMDR Output Options - Caller ID Name Output Method.</td>
			</tr>
			<tr>
				<td class="confluenceTd"><b>80-05-01</b></td>
				<td class="confluenceTd"><span class="keyword">1</span></td>
				<td class="confluenceTd">Date Format for SMDR and System Reports.</td>
			</tr>
		</tbody>
	</table>
</ol>

<h2>Configuring TIM Enterprise<Plus</h2>

<p>Below you will find steps on how to configure TIM EnterprisePlus to listen for SMDR data from your NEC XN120:</p>

<ol>
	<li>Browse to TIM EnterprisePlus as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Go<li>Click theon the pointsite inconfigured the Directory where you need to add during the PBXsetup Objectwizard and add a PBX with the name 'NEC XN120'.</li>
	<li>Left-click on it and select <span class="button no_margin">Properties</span>.</li>
	<li>From the span>or create a new site and click <span class="button no_margin">General<>Properties</span> settings tab select <span class="keyword">NEC XN120</span> from the PBX model list.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_enterpriseplus/pbx/nec_xn120_1.png" alt="NEC XN120" />
	<li>In<li>Within the <span class="button no_margin">Connection<reference">Site Properties</span> tabwindow, select <span class="keyword">Establish>NEC TCPXN120</span> connectionfrom to PBX<the <span class="reference">PBX model</span> from drop-down list.</li>
	<li>In the <span class="reference">Connection method</span> field select <span class="keyword">Actively connect to PBX</span> from the drop-down list.</li>
	<li>In the <span class="reference">Host</span> field enter the IP Address of your NEC XN120.</li>
	<li>Leave<li>In the <span class="reference">Port</span> field blankenter in the port configured in programming code <b>10-20-01</b>.</li>
	<li>Leave the <span class="reference">Username</span> field blank and enter your <span class="reference">Password</span> fields blank.</li>
	<li>In the <span class="reference">IP>Connection script</span> field select <span class="keyword">Generic Simple</span> from the drop-down list.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/nec_xn120_2.png" alt="NEC XN120" />
</ol>