Field | Description |
---|---|
Host | The IP address or hostname of the BCM PBX |
Username | The username required to access the CDR events |
Password | The password required to access the CDR events |
App ID | The unique ID number given to each source of data. |
XML file
This method monitors an XML file for new nodes. To specify which nodes to monitor, an XPath query is used; to identify which nodes are new, a unique element is required. Default properties are designed to work with the ticketcollector.xml file produces by an Alcatel OmniPCX Enterprise PBX.
...
Field | Description |
---|---|
Location | The full filename of the XML file to be monitored. The {app} variable can be used to specify the program data location of the running service |
X-Path query | The XPath query to use when testing for new nodes |
Checksum node | The unique node(element) to be used to track which nodes have been added since the last check |
Outer element | The name of the outer XML element to be used to contain any new nodes when the new XML document is created for output |
Check interval | The time interval the system is checking for a new node. |
Delay | A value, in milliseconds, that specifies the artificial delay that is waited when a change in the source XML file is discovered. |
...