Quick Search
Browse
Pages
Blog
Labels
Attachments
Mail
Advanced
What’s New
Space Directory
Feed Builder
Keyboard Shortcuts
Confluence Gadgets
Log In
Dashboard
TIM Plus
Copy Page
You are not logged in. Any changes you make will be marked as
anonymous
. You may want to
Log In
if you already have an account. You can also
Sign Up
for a new account.
This page is being edited by
.
Paragraph
Paragraph
Heading 1
Heading 2
Heading 3
Heading 4
Heading 5
Heading 6
Preformatted
Quote
Bold
Italic
Underline
More colours
Strikethrough
Subscript
Superscript
Monospace
Clear Formatting
Bullet list
Numbered list
Outdent
Indent
Align left
Align center
Align right
Link
Table
Insert
Insert Content
Image
Link
Attachment
Symbol
Emoticon
Wiki Markup
Horizontal rule
tinymce.confluence.insert_menu.macro_desc
Info
JIRA Issue
Status
Gallery
Tasklist
Table of Contents
Other Macros
Undo
Redo
Find/Replace
Keyboard Shortcuts Help
<p>These instructions help you configure your AYCTelecom IPcts to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.</p><p><img class="editor-inline-macro" src="/plugins/servlet/confluence/placeholder/macro?definition=e3BieHN1bW1hcnk6U3VwcG9ydGZpbGVzMT1BWUNUZWxlY29tIElQQ1RTLlREVHxTdXBwb3J0ZmlsZXMyPUFZQ1RlbGVjb20gSVBDVFMuVERTfFJlcXVpcmVkdGFzazE9Q29uZmlndXJlIHRoZSBTTURSIG91dHB1dHxSZXF1aXJlZHRhc2syPUNvbmZpZ3VyZSBUSU0gUGx1c3xDb25uZWN0aW9uPUxpc3RlbmluZyBjb25uZWN0aW9ufFJlcXVpcmVkVGFzazE9Q29uZmlndXJlIHRoZSBTTURSIG91dHB1dHxSZXF1aXJlZFRhc2syPUNvbmZpZ3VyZSBUSU0gUGx1c30&locale=en_GB&version=2" data-macro-name="pbxsummary" data-macro-parameters="Connection=Listening connection|RequiredTask1=Configure the SMDR output|RequiredTask2=Configure TIM Plus|Requiredtask1=Configure the SMDR output|Requiredtask2=Configure TIM Plus|Supportfiles1=AYCTelecom IPCTS.TDT|Supportfiles2=AYCTelecom IPCTS.TDS"></p><table class="wysiwyg-macro" data-macro-name="html" style="background-image: url(/plugins/servlet/confluence/placeholder/macro-heading?definition=e2h0bWx9&locale=en_GB&version=2); background-repeat: no-repeat;" data-macro-body-type="PLAIN_TEXT"><tr><td class="wysiwyg-macro-body"><pre><a id="Configure the SMDR output"></a></pre></td></tr></table><h2>Configuring your SMDR output</h2><p>Follow the steps below to set up the SMDR output of your IPcts through its management web page:</p><ol><li>Log in to your AYCTelecom IPcts management web page.</li><li>Select the <span class="button no_margin">System</span> tab</li><li>Select the <span class="button no_margin">SMDR/Log</span> tab and configure the fields on the page as below:</li><ul><li><strong>SMDR Server Enabled:</strong> Enable the check box.</li><li><strong>SMDR Server Output:</strong> Choose <span class="keyword">Network Address</span>.</li><li><strong>SMDR Client IP Address:</strong> Enter the IP address of the computer running TIM Plus.</li><li><strong>SMDR Client Port:</strong> Enter the TCP port number you want to send the SMDR data to. You can use any free TCP port, but we would recommend one in the 9000 range.</li></ul><li>Click the <span class="button no_margin">Update</span> button.</li><li>Click the <span class="button no_margin">Commit Changes</span> button at the top of the page so save your settings.</li></ol><p>Here is an example screenshot of the SMDR configuration screen from the AYCTelecom IPcts management web page:</p><p><img class="editor-inline-macro" src="/plugins/servlet/confluence/placeholder/macro?definition=e3NjcmVlbnNob3RtYWNybzpCb3JkZXI9ZmFsc2V8U2hhZG93PWZhbHNlfFVSTD0vZG93bmxvYWQvYXR0YWNobWVudHMvNDgxNzA0Ny9heWNfdGVsZWNvbV8xLnBuZ30&locale=en_GB&version=2" data-macro-name="screenshotmacro" data-macro-parameters="Border=false|Shadow=false|URL=/download/attachments/4817047/ayc_telecom_1.png"></p><table class="wysiwyg-macro" data-macro-name="html" style="background-image: url(/plugins/servlet/confluence/placeholder/macro-heading?definition=e2h0bWx9&locale=en_GB&version=2); background-repeat: no-repeat;" data-macro-body-type="PLAIN_TEXT"><tr><td class="wysiwyg-macro-body"><pre><a id="Configure TIM Plus"></a></pre></td></tr></table><h2>Configuring TIM Plus</h2><p>Follow the steps below to configure TIM Plus to listen for SMDR data from your AYCTelecom IPcts phone system:</p><ol><li>Click on the <span class="button no_margin">Directory</span> tab.</li><li>Choose the site you want to configure and click <span class="button no_margin">Properties</span>.<br /><img class="editor-inline-macro" src="/plugins/servlet/confluence/placeholder/macro?definition=e3NjcmVlbnNob3RtYWNybzpCb3JkZXI9ZmFsc2V8VVJMPS9kb3dubG9hZC9hdHRhY2htZW50cy80ODE3MDQ3L2F5Y190ZWxlY29tXzIucG5nfQ&locale=en_GB&version=2" data-macro-name="screenshotmacro" data-macro-parameters="Border=false|URL=/download/attachments/4817047/ayc_telecom_2.png"></li><li>In the <span class="reference">Site Properties</span> window, select <span class="keyword">AYCTelecom IPCTS</span> from the <span class="reference">PBX model</span> drop-down list.</li><li>In the <span class="reference">Connection method</span> field, select <span class="keyword">Listen for connections from PBX</span> from the drop-down list.</li><li>Leave the <span class="reference">Host</span> field blank.</li><li>In the <span class="reference">Port</span> field, enter the TCP port that was configured on your AYCTelecom IPcts (e.g. <img class="editor-inline-macro" src="/plugins/servlet/confluence/placeholder/macro?definition=e2tleXdvcmRtYWNybzpMYWJlbD05MDAwfQ&locale=en_GB&version=2" data-macro-name="keywordmacro" data-macro-parameters="Label=9000">).</li><li>Click on the <span class="button no_margin">Save</span> button to apply the changes.</li></ol>
Attachments
Labels
Location
< Edit
Preview >
Loading…
Save
Cancel
Next hint
search
attachments
weblink
advanced