Quick Search
Browse
Pages
Blog
Labels
Attachments
Mail
Advanced
What’s New
Space Directory
Feed Builder
Keyboard Shortcuts
Confluence Gadgets
Log In
Dashboard
TIM Plus
Copy Page
You are not logged in. Any changes you make will be marked as
anonymous
. You may want to
Log In
if you already have an account. You can also
Sign Up
for a new account.
This page is being edited by
.
Paragraph
Paragraph
Heading 1
Heading 2
Heading 3
Heading 4
Heading 5
Heading 6
Preformatted
Quote
Bold
Italic
Underline
More colours
Strikethrough
Subscript
Superscript
Monospace
Clear Formatting
Bullet list
Numbered list
Outdent
Indent
Align left
Align center
Align right
Link
Table
Insert
Insert Content
Image
Link
Attachment
Symbol
Emoticon
Wiki Markup
Horizontal rule
tinymce.confluence.insert_menu.macro_desc
Info
JIRA Issue
Status
Gallery
Tasklist
Table of Contents
Other Macros
Undo
Redo
Find/Replace
Keyboard Shortcuts Help
<p>These instructions help you configure your Skype for Business phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.</p><p><img class="editor-inline-macro" src="/plugins/servlet/confluence/placeholder/macro?definition=e3BieHN1bW1hcnk6U3VwcG9ydGZpbGVzMT1Ta3lwZSBmb3IgQnVzaW5lc3MuVERUfFN1cHBvcnRmaWxlczI9U2t5cGUgZm9yIEJ1c2luZXNzLlREU3xTdXBwb3J0ZmlsZXMzPVNreXBlIGZvciBCdXNpbmVzcy5EQlN8Q29ubmVjdGlvbj1EU04gY29ubmVjdGlvbnxSZXF1aXJlZFRhc2sxPUNvbmZpZ3VyZSB0aGUgU01EUiBvdXRwdXR8UmVxdWlyZWRUYXNrMj1TZXQgdXAgYSBEU04gY29ubmVjdGlvbnxSZXF1aXJlZFRhc2szPUNvbmZpZ3VyZSBUSU0gUGx1c30&locale=en_GB&version=2" data-macro-name="pbxsummary" data-macro-parameters="Connection=DSN connection|RequiredTask1=Configure the SMDR output|RequiredTask2=Set up a DSN connection|RequiredTask3=Configure TIM Plus|Supportfiles1=Skype for Business.TDT|Supportfiles2=Skype for Business.TDS|Supportfiles3=Skype for Business.DBS"></p><table class="wysiwyg-macro" data-macro-name="html" style="background-image: url(/plugins/servlet/confluence/placeholder/macro-heading?definition=e2h0bWx9&locale=en_GB&version=2); background-repeat: no-repeat;" data-macro-body-type="PLAIN_TEXT"><tr><td class="wysiwyg-macro-body"><pre><a id="Configure the SMDR output"></a></pre></td></tr></table><h2>Configuring the SMDR output</h2><p class="reference">The Skype for Business phone system writes its CDR data to a MSSQL database called <span class="reference">LcsCDR </span>on the <span class="reference">Monitoring Server</span>. In order for TIM Plus to connect to the database and collect the call logging data, a Windows or SQL authenticated login will have to be created to allow access. Contact your system maintainer if you are not familiar with this procedure.</p><p>The following information is required for TIM Plus to connect to the <span class="reference">LcsCDR</span> database:</p><ul><li>IP address or hostname of the <span class="reference">Monitoring Server</span> where the <span class="reference">LcsCDR</span> database resides.</li><li>Username and Password of the <span class="reference">LcsCDR</span> database.</li></ul><table class="wysiwyg-macro" data-macro-name="html" style="background-image: url(/plugins/servlet/confluence/placeholder/macro-heading?definition=e2h0bWx9&locale=en_GB&version=2); background-repeat: no-repeat;" data-macro-body-type="PLAIN_TEXT"><tr><td class="wysiwyg-macro-body"><pre><a id="Set up a DSN connection"></a></pre></td></tr></table><h2>Setting up a DSN connection</h2><p>To enable TIM Plus to work with your Skype for Business phone system, you first need to set up a DSN connection by following the steps below:</p><ol><li>Open Windows Control Panel and select the <img class="editor-inline-macro" src="/plugins/servlet/confluence/placeholder/macro?definition=e2J1dHRvbm1hY3JvOkxhYmVsPUFkbWluaXN0cmF0aXZlIFRvb2xzfQ&locale=en_GB&version=2" data-macro-name="buttonmacro" data-macro-parameters="Label=Administrative Tools"> icon</li><li><p>Double-click on the <span class="button no_margin">Data Sources (ODBC)</span> icon to open the <span class="reference">ODBC Data Source Administrator</span> window</p><table class="wysiwyg-macro" data-macro-name="info" style="background-image: url(/plugins/servlet/confluence/placeholder/macro-heading?definition=e2luZm99&locale=en_GB&version=2); background-repeat: no-repeat;" data-macro-body-type="RICH_TEXT"><tr><td class="wysiwyg-macro-body"><p class="reference">For a 64 bit system, access the <span class="reference">ODBC Data Source Administrator </span>from the following location <span class="reference">C:\Windows\SysWOW64\odbcad32.exe</span></p></td></tr></table></li><li>Click on the <span class="button no_margin">System DSN</span> tab.</li><li>Click on the <span class="button no_margin">Add</span> button.</li><li>Select <span class="keyword">SQL Native Client</span> from the driver list and click <span class="button no_margin">Finish</span>.</li><li>In the <span class="reference">Name</span> field, enter <span class="keyword">lync.</span></li><li>In the <span class="reference">Description</span> field, enter <span class="keyword">TIM Plus link to LcsCDR.<br /></span></li><li>In the <span class="reference">Server</span> field, enter the IP address or hostname of your <span class="reference">Monitoring Server.</span></li><li>In the <span class="reference">Username</span> field, enter the username for your <span class="reference">LcsCDR</span> database.</li><li>In the <span class="reference">Password</span> field, enter the password for your <span class="reference">LcsCDR</span> database.</li><li>In the <span class="reference">Database</span> drop-down list, select <span class="keyword"> </span><span class="reference">LcsCDR.</span></li><li>Click on the <span class="button no_margin">Test</span> button to confirm the information you entered is correct and that the connection is successful.</li><li>Click on the <span class="button no_margin">OK</span> button to close the window.<br /><br /></li></ol><p>An example of an ODBC entry is shown below:</p><p><img class="editor-inline-macro" src="/plugins/servlet/confluence/placeholder/macro?definition=e3NjcmVlbnNob3RtYWNybzpCb3JkZXI9ZmFsc2V8U2hhZG93PWZhbHNlfFVSTD0vZG93bmxvYWQvYXR0YWNobWVudHMvMTY3MTIwODEvTHluY19PREJDLnBuZ30&locale=en_GB&version=2" data-macro-name="screenshotmacro" data-macro-parameters="Border=false|Shadow=false|URL=/download/attachments/16712081/Lync_ODBC.png"></p><table class="wysiwyg-macro" data-macro-name="html" style="background-image: url(/plugins/servlet/confluence/placeholder/macro-heading?definition=e2h0bWx9&locale=en_GB&version=2); background-repeat: no-repeat;" data-macro-body-type="PLAIN_TEXT"><tr><td class="wysiwyg-macro-body"><pre><a id="Configure TIM Plus"></a></pre></td></tr></table><h2>Configuring TIM Plus</h2><p>Once the DSN connection has been set up, log in to TIM Plus and perform the steps below:</p><ol><li>Click on the <span class="button no_margin">Directory</span> tab.</li><li>Choose the site you want to configure and click <span class="button no_margin">Properties</span>.<br /><img class="editor-inline-macro" src="/plugins/servlet/confluence/placeholder/macro?definition=e3NjcmVlbnNob3RtYWNybzpCb3JkZXI9ZmFsc2V8VVJMPWh0dHA6Ly9kb2NzLnRyaS1saW5lLmNvbS9kb3dubG9hZC9hdHRhY2htZW50cy8xNjcxMjA4MS9MeW5jXzEucG5nfQ&locale=en_GB&version=2" data-macro-name="screenshotmacro" data-macro-parameters="Border=false|URL=http://docs.tri-line.com/download/attachments/16712081/Lync_1.png"></li><li>In the <span class="reference">Site Properties</span> window, select <span class="keyword">Skype for Business</span> from the <span class="reference">PBX model</span> drop-down list.</li><li>In the <span class="reference">Connection method</span> field, select <span class="keyword">Connect to a system DSN</span> from the drop-down list.</li><li class="keyword">In the <span class="reference">DSN name</span> field, select <span class="keyword">lync </span>from the drop-down list.</li><li>In the <span class="reference">Frequency</span> field, enter <span class="keyword">5</span>.</li><li>In the <span class="reference">DB script</span> field, select <span class="keyword">Skype for Business</span> from the drop-down list.</li><li>Click on the <span class="button no_margin">Save</span> button to apply the settings.</li></ol>
Attachments
Labels
Location
< Edit
Preview >
Loading…
Save
Cancel
Next hint
search
attachments
weblink
advanced