Showing 1-10 of 42 for ancestorIds:4817010 AND database

  • Swyx The Swyx telephone system can be configured to send its SMDR over a database connection or it can be outputted to a file. Click on one of the links below that relates to your preferred connection method.
  • Unify (Siemens) OpenScape Business The Unify OpenScape Business can be configured to send its SMDR data over an IP or database connection. The links below show details for both connection methods.
  • Unify (Siemens) OpenOffice The Unify (Siemens) OpenOffice can be configured to send its SMDR data over an IP or database connection. Click on one of the links below that relates to your preferred connection method.
  • CDR data to a MSSQL database. In order for TIM Enterprise to connect to the database and collect the call logging data, you need to create a username and password in the MSSQL database on the Swyx server. Contact your system maintainer if you are not familiar with this procedure. The following information is required
  • to a MySQL database called . In order for TIM Plus to connect to the database and collect the call logging data, you need to create a username and password in the MySQL database on the ShoreWare Server. Contact your system maintainer if you are not familiar with this procedure. The following information is required
  • phone system writes its CDR data to a MSSQL database called LcsCDR on the Monitoring Server. In order for TIM Plus to connect to the database and collect the call … with this procedure. The following information is required for TIM Plus to connect to the LcsCDR database: IP address or hostname of the Monitoring Server where the LcsCDR
  • in a Microsoft SQL Server database. However, by default, this functionality is not enabled. To enable it, the following settings must be configured … its call records to a table named in a database entitled . Rather than have TIM Plus read and remove CDRs from the live table, we recommend you replicate
  • below; Cisco Database Layer Monitor (Depending on Cisco UCM version, you may not have this service) Cisco CDR Repository Manager Cisco CDR Agent Cisco CAR
  • If the system was upgraded from HiPath 3000, but the database was retyped subsequently, the data format will use as a separator If the system was new, the data format will use as a separator If the HiPath 3K database was simply converted and not retyped, no change will be required, since both the old and the new database
  • database of TIM Plus with thirdparty applications such as CRM systems; for this type of solution, we would recommend our TIM Enterprise product. Software Microsoft